L72.15-0002-06
Illustrated on models 667.35, 668.35, 670.35/37/45
A, B Gap
C, D Ridge pattern
| Inspecting | ||
1 | Check gaps (A, B) and ridge patterns (C, D) on front door all the way around | Feeler gage If values deviate | |
Adjust door gap | |||
Adjust door installation depth | |||
Gap for front door all the way around | |||
Installation depth for front door to A, | |||
Ridge pattern offset for front door to side wall paneling | |||
2 | Check front door for easy motion |
Adjustment values for front door
Number | Designation | Models | |
BE72.10-N-1001-01C | Gap for front door all the way around | mm | 101 |
BE72.10-N-1002-01C | Installation depth for front door to A, | mm | 0 (+1/-2) |
BE72.10-N-1003-01C | Ridge pattern offset for front door to side wall paneling | mm | 02 |
129 589 03 21 00
Feeler gauge