P54.10-2652-07
3 | Cover | 5 | Floor covering | 6 | Positive battery terminal | ||
4 | Floor mat |
| Remove | ||
Topical note | Notes on battery | ||
1 | Move front passenger seat all the way up and down | ||
2 | Unclip trim (3) toward front and remove | ||
3 | Fold floor mat (4) forward and lift up floor covering (5) slightly to gain access to positive terminal battery (6) as well as to battery minus pole (arrow A) | ||
| Check | ||
4 | Visual inspection for external leaks | If leakage found Replace battery, see: | |
| |||
Remove/install battery | |||
Dispose of defective battery properly and in an environmentally compatible manner. | |||
Danger | Risk of fire/risk of explosion due to short circuit and escaping oxyhydrogen gas. Risk of (burn) injury caused by caustic burns to eyes, skin and mucous membranes from battery electrolyte/mist, short circuit and arcing. Risk of poisoning caused by swallowing battery electrolyte or absorption of lead through the skin or body orifices. Risk of death due to voltage U >= 30 V AC and U >= 60 V DC. | No fires, sparks, open flames, or smoking. Wear acid-resistant gloves, clothing, and glasses. Pour battery acid only into suitable and appropriately marked containers. | |
5 | Check battery | ||
Cold cranking amps as per EN | |||
Commercially available devices/tools | |||
Battery capacity 12 Ah | |||
Battery capacity 30 Ah | |||
Battery capacity 35 Ah | |||
Battery capacity 46 Ah | |||
Battery capacity 60 Ah VRLA/AGM | |||
Battery capacity 60 Ah | |||
Battery capacity 62 Ah | |||
Battery capacity 70 Ah VRLA/AGM | |||
Battery capacity 74 Ah | |||
Battery capacity 80 Ah VRLA/AGM | |||
Battery capacity 84 Ah | |||
Battery capacity 90 Ah VRLA | |||
Battery capacity 95 Ah VRLA | |||
Battery capacity 100 Ah | |||
Danger | Risk of fire/risk of explosion due to short circuit and escaping oxyhydrogen gas. Risk of (burn) injury caused by caustic burns to eyes, skin and mucous membranes from battery electrolyte/mist, short circuit and arcing. Risk of poisoning caused by swallowing battery electrolyte or absorption of lead through the skin or body orifices. Risk of death due to voltage U >= 30 V AC and U >= 60 V DC. | No fires, sparks, open flames, or smoking. Wear acid-resistant gloves, clothing, and glasses. Pour battery acid only into suitable and appropriately marked containers. | |
6 | Reduce increased voltage after charging process | On a battery that is disconnected from the on-board electrical system and with the message "Surface voltage" in the display of the Midtronics battery tester and analyzer MCR 717 | |
After reducing increased voltage, test battery again. | |||
Commercially available devices/tools | |||
7 | Charge battery | If test code "Charge and test" is displayed on Midtronics battery tester and analyzer MCR 717 | |
After charging, test battery again. | |||
| Install | ||
8 | Position floor covering (5) and floor mat (4) | ||
9 | Install cover (3) | ||
10 | Move front passenger seat to default position |
Test and adjustment values for battery |
Number | Designation | Model all (4xWD, CAR, smart) | |||
BE54.10-P-1002-01A | Battery capacity 30 Ah | Battery test at 20 °C | Acid density | kg/dm3 | 1,24 |
Maximum permissible difference between individual battery cells | kg/dm3 | 0,04 | |||
Load current | A | 90 | |||
Load time | s | 10 | |||
Voltage | V | 10 | |||
Cold cranking amps | As per EN | A | 540 |
Test and adjustment values for battery |
Number | Designation | Model all (4xWD, CAR, smart) | |||
BE54.10-P-1003-01A | Battery capacity 35 Ah | Battery test at 20 °C | Acid density | kg/dm3 | 1,24 |
Maximum permissible difference between individual battery cells | kg/dm3 | 0,04 | |||
Load current | A | 100 | |||
Load time | s | 10 | |||
Voltage | V | 10 | |||
Cold cranking amps | As per EN | A | 520 |
Test and adjustment values for battery |
Number | Designation | Model all (4xWD, CAR, smart) | |||
BE54.10-P-1005-01A | Battery capacity 46 Ah | Battery test at 20 °C | Acid density | kg/dm3 | 1,24 |
Maximum permissible difference between individual battery cells | kg/dm3 | 0,04 | |||
Load current | A | 140 | |||
Load time | s | 10 | |||
Voltage | V | 10 | |||
Cold cranking amps | As per EN | A | 420 |
Test and adjustment values for battery |
Number | Designation | Model all (4xWD, CAR, smart) | |||
BE54.10-P-1009-01A | Battery capacity 62 Ah | Battery test at 20 °C | Acid density | kg/dm3 | 1,24 |
Maximum permissible difference between individual battery cells | kg/dm3 | 0,04 | |||
Load current | A | 190 | |||
Load time | s | 10 | |||
Voltage | V | 10 | |||
Cold cranking amps | As per EN | A | 480 |
Test and adjustment values for battery |
Number | Designation | Model all (4xWD, CAR, smart) | |||
BE54.10-P-1011-01A | Battery capacity 74 Ah | Battery test at 20 °C | Acid density | kg/dm3 | 1,24 |
Maximum permissible difference between individual battery cells | kg/dm3 | 0,04 | |||
Load current | A | 265 | |||
Load time | s | 10 | |||
Voltage | V | 10 | |||
Cold cranking amps | As per EN | A | 680 |
Test and adjustment values for battery |
Number | Designation | Model all (4xWD, CAR, smart) | |||
BE54.10-P-1016-01A | Battery capacity 100 Ah | Battery test at 20 °C | Acid density | kg/dm3 | 1,24 |
Maximum permissible difference between individual battery cells | kg/dm3 | 0,04 | |||
Load current | A | 300 | |||
Load time | s | 10 | |||
Voltage | V | 10 | |||
Cold cranking amps | As per EN | A | 760 |
Documente menționate
- ah5410p000101a Indicaţii pentru acumulator
- ah5410p000101a
- ar5410p0005rt
- ar5410p112901a Verificaţi acumulatorul
- ar5410p112903a Reduceţi tensiunea mărită după procesul de încărcare
- ar5410p1130rt
- as5410z000101a Pericol de incendiu/explozie, ca urmare a scurtcircuitului și a gazului detonant evacuat. Pericol de combustie/pericol de rănire, ca urmare a iritării ochilor, a pielii şi a mucoasei, ca urmare a electrolitului de acumulator/vaporilor