ar2010p3000olf

Remove/install coolant pump switchover valve

Tip ar · temă 20.10 · versiune 0100 · 2014-04-11

Valabil pentru: ENGINE 651 in MODEL 222

Nu este disponibil în „ro”; afișat în Engleză.

Încadrare

Grupă funcțională 1 Motor › 20 Răcire motor › 20.10 Pompă lichid răcire, termostat lichid de răcire — Seria 222 · Seria 651

EinPAS 15 Motor › 15.25 Sistem răcire motor › 15.25.13 Conductă/Furtun/Supapă — Seria 222 · Seria 651

AR20.10-P-3000OLF

Remove/install coolant pump switchover valve

27.03.2014

ENGINE

651 in MODEL 222

Remove/install coolant pump switchover valve

1

Electrical connection

2

Vacuum hoses

3

Retaining tab

4

Coolant pump switchover valve

P07.02-2179-06

Danger !

Risk of injury caused by fingers being jammed or pinched when removing, installing or aligning hoods, doors, trunk lid/rear-end door or sliding roof.

No parts of the body or limbs should be within the operating area when the components are moving.

AS00.00-Z-0011-01A

Remove/install

1

Remove engine cover

Installation: Ensure correct seating.

2

Remove engine air intake duct upstream of air filter

3

Release and disconnect electrical connection (1) on coolant pump switchover valve (4)

4

Mark vacuum hoses (2)

5

Detach vacuum hoses (2) at coolant pump switchover valve (4)

Installation: Observe marking on vacuum hoses (2).

6

Release and detach coolant pump switchover valve (4) on retaining tab (3)

7

Install in the reverse order