1 | Drain fitting |
2 | Drain screw |
P20.00-A078-06
Warning | Risk of injury due to fan starting unexpectedly | Do not reach into the rotation or hazard area of the fan. Wear closed and close-fitting work clothes. | |
Warning | Risk of injury. Skin or eye injuries may result when handling hot or glowing objects. | Wear protective gloves, protective clothing and safety glasses, if necessary. | |
Warning | Risk of injury to skin and eyes suffering scalding from contact with hot coolantspray. Risk of poisoning from swallowing coolant. | Do not open cooling system unless coolant temperature is below 90 °C. Open cap slowly and release the pressure. Do not pour coolant into beverage containers. | |
Topical note | Notes on avoiding damage through contamination and foreign objects | ||
Topical note | Notes on coolant | ||
| Remove | ||
1 | Slowly open cap, release overpressure and then remove from coolant expansion reservoir. | ||
2 | Remove center engine compartment lining and front center engine compartment lining. | ||
Drain off | |||
3 | Insert suitable hose on the drain fitting (1) at bottom right on engine cooling system cooler. | ||
4 | Open drain screw (2) on the engine cooling system cooler and drain off coolant in a suitable container. | | |
Observe regulations for disposal of coolant. | |||
5 | Close drain screw (2) on engine cooling system cooler and detach drain hose. | ||
Pour in | |||
6 | Pour in coolant and bleed engine cooling system. | ||
Notes on coolant level | |||
Work procedure must be complied with when filling cooling system. | |||
Re-use clean coolant. | |||
Test pressure for pressure-testing the engine cooling system | |||
Engine 254 in model 213.073Cooling system | |||
Pressure pump | |||
Electric vacuum pump | |||
NTKL Adaption | |||
Test cap | |||
Cooler vacuum filling device | |||
| Check | ||
7 | Check engine cooling system for leak tightness. | ||
| Install | ||
8 | Install center engine compartment lining and front center engine compartment lining. |
285 589 01 21 00
NTKL Adaption
210 589 00 91 00
Test cap
124 589 24 21 00
Pressure pump
285 589 02 21 00
Electric vacuum pump
285 589 00 21 00
Cooler vacuum filling device
Documente menționate
- ah0000p500001a Indicaţii pentru evitarea defecţiunilor din cauza impurităţilor şi corpurilor străine
- ah2000n208001a Indicaţii pentru lichid de răcire
- ah2000p114201cw Indicaţii pentru nivelul lichidului de răcire
- ar2000p1010mrv
- ar2000p114204olc Completaţi lichidul de răcire şi aerisiţi sistemul de răcire
- ar6120p1105lwe
- as0000z000201a Pericol de rănire la piele şi ochi prin manipulare cu obiecte fierbinţi sau incandescente
- as2000z000101a Pericol de rănire la piele şi ochi prin opărire cu lichid de răcire fierbinte pulverizat afară. Pericol de otrăvire datorită înghiţirii lichid de răcire.
- as2040z000101a Pericol de rănire prin pornirea bruscă a ventilatorului