1 | Level sensor |
2 | Reservoir fastening strap |
3 | Reservoir |
B14.40-0116-11
| Remove/install | ||
Warning | Risk of burn injuries and scalding when working at AdBlue lines and the components attached to them. Risk of injury to skin and eyes when handling AdBlue. Risk of poisoning caused by swallowing AdBlue | Pour AdBlue into suitable containers only. Wait until the pressure is released before starting any work on the exhaust aftertreatment system. | |
1 | Drain the AdBlue from reservoir (3) | ||
Notes on use, material properties and handling of AdBlue® | |||
Do not reuse drained AdBlue, because it may be contaminated and thus cause damage to the system. | |||
2 | Remove the level sensor (1) | ||
3 | Remove the reservoir fastening strap (2) | ||
4 | Remove the reservoir (3) | ||
5 | Install on the reverse order |