ar1440d204901ae

Install external pneumatic pressure reducing valve on pump module

Tipo ar · tema 14.40 · versão 0100 · 2010-07-16

Válido para: ENGINE 900.917 /918 /919 in MODEL 668.35, 670.35 /37 /45

Não disponível em “pt”; apresentado em Inglês.

Onde se situa

Grupo funcional 1 Motor › 14 Coletor de escapamento, freio-motor, instalação de purificação dos gases de escape › 14.40 Processamento posterior dos gases de escape, AdBlue — Série 668 (modelos 35*) · Série 670 (modelos 35*, 37*, 45*) · Série 900 (modelos 917, 918, 919)

EinPAS 15 Motor › 15.40 Sistema dos gases de escape/pós-tratamento dos gases de escape › 15.40.13 Tubulação/mangueira/válvula — Série 668 (modelos 35*) · Série 670 (modelos 35*, 37*, 45*) · Série 900 (modelos 917, 918, 919)

AR14.40-D-2049-01AE

Install external pneumatic pressure reducing valve on pump module

Exhaust aftertreatment, Blue Tec

Number

Designation

Engine
900.9
in model
668, 670

BA14.40-N-1028-02E

Screw plug on pump module

Nm

20

BA14.40-N-1029-02E

Sleeve for external pressure relief valve to pump module

Nm

45

BA14.40-N-1030-02E

Hexagon nut on sleeve for external pressure relief valve

Nm

30

Install external pneumatic pressure reducing valve on pump module

D14.40-0106-11

1 Remove connection fitting (1) on the AdBlue SCR (M26/1) pump.

2 Remove internal pressure reducing valve piston (2) together with spring (3), the spring cup (4) and the ball (5).

In the case of jammed pressure reducing valve pistons (2) screw in a bolt, e.g. M470, in its inside thread and use this to pull out the pressure reducing valve piston (2).
The ball (5) is very small and can easily be overlooked. Ensure that it does not remain in the AdBlue SCR (M26/1) pump.

3 Remove (6) return line fitting on the AdBlue SCR (M26/1) pump.

Install external pneumatic pressure reducing valve on pump module

D14.40-0107-11

4 Screw in screw plug (7) with new sealing ring on the AdBlue SCR (M26/1) pump.

Pay attention to tightening torque.

5 Attach external pneumatic pressure relief valve (8) to the AdBlue SCR (M26/1) pump.

Tighten down sleeve on hexagon (arrow).
Turn the external pneumatic pressure relief valve (8) in such a way that after installation of the AdBlue SCR (M26/1) pump the AdBlue® return line can be attached to the connection fitting.
Loosen the upper hexagonal nut and align external pneumatic pressure relief valve (8) if necessary and tighten down upper hexagonal nut.
Observe tightening torques.

Install external pneumatic pressure reducing valve on pump module

D14.40-0108-11

6 Replace straight connection fitting on the air line (9) with an elbow fitting (11); extend air line (9) starting from the T-piece (10) if necessary.

The air line (9) must be routed tension and chafing free.