gf8370p3012b

Voltage too low or too high during heating mode, function

Typ gf · temat 83.70 · wersja 0101 · 1999-08-06

Dotyczy: MODEL 129 as of 1.6.97 with CODE (228) Stationary heater

Niedostępne w języku „pl”; wyświetlono w języku Angielski.

Umiejscowienie

Grupa funkcyjna 3 Nadwozie › 83 Klimatyzacja › 83.70 Ogrzewanie w czasie postoju, dodatkowe, nagrzewnica dodatkowa — Seria 129

GF83.70-P-3012B

Voltage too low or too high during heating mode, function

10.7.97

MODEL 129 as of 1.6.97 with CODE (228) Stationary heater

Voltage too low or too high during heating mode, function

P83.70-0393-09

1 Burner housing

2 Heat exchanger

3 Heater circuit thermostat

A6m1 Coolant circulation pump

Y23 Fuel metering pump

B Thermostat setting, open auxiliary circuit

A6m2 Combustion air blower

A6n1 Stationary heater/heater booster control module

N34 Stationary heater timer

Function sequence

1 Coolant temperature:> 59 °C :
The thermostat (3) is switched to heating mode, the stationary heater auxiliary circuit is connected to the cooling and heater circuit of the vehicle.

2 The heater operates at partial load or full load.

3 The stationary heater control module (A6n1) monitors the power supply to the stationary heater.

4 The control module recognizes a malfunction in the power supply:

The voltage is < 10.0 - 10.5 V for more than 20 s. The control module starts a malfunction switch-off to protect the battery from being discharged.

The voltage exceeds 15.5 V for more than 6 s. The control module starts a malfunction switch-off to protect the electric and electronic heater components.

5 The fuel metering pump (Y23) switches off thereby interrupting the combustion.

6 The actuation of the vehicle blower is interrupted and the blower is switched off.

7 The heater malfunction shut-off delay for cooling the heater and for purging the combustion chamber starts for approx. 110 s. The combustion air blower reduces its speed during the first 40 s of the shut-off delay to partial load operation and then increases again to almost full load operation.

8 The heater shut-off delay is terminated. The combustion air blower and the coolant circulation pump (A6m1) are switched off.

To reset switch heater on and off again after eliminating the cause of the malfunction.

Burner housing, location/purpose/design

GF83.70-P-4000A

Heat exchanger, location/purpose/design

GF83.70-P-4001A

Stationary heater/heater booster control module, location/purpose

GF83.70-P-4002A

Coolant circulation pump, location/purpose

GF83.70-P-4003A

Combustion air blower, location/purpose

GF83.70-P-4004A

Stationary heater timer, location/purpose/function

GF83.70-P-4007A

Fuel metering pump, location/purpose

GF83.70-P-4008A

Heater circuit thermostat location/purpose

GF83.70-P-4051A

Powiązane dokumenty