1 | Glow plug |
2 | Combustion air blower |
3 | Electrical connection |
4 | Seal |
S83.70-4676-05
| Remove/install | ||
1 | Detach combustion air blower (2) from heater | ||
The electrical lines of combustion air blower (2) are not removed. | |||
2 | Remove electrical lines of glow plug (1) from electrical connector (3) | Installation: Make sure that slots are correctly assigned in electrical connector (3). | |
Wiring harness repair kit, basic | |||
3 | Remove glow plug (1) | Installation: Check seal (4) is in correct installation position. | |
4 | Install in the reverse order | ||
| Check | ||
Danger ! | Risk of explosion caused by fuel vapors igniting, risk of poisoning caused by inhaling combustible gases and risk of injury caused by burns during and after operation of heater unit | Do not operate stationary heater, auxiliary heater or engine with heater booster in closed rooms or when refueling. Allow heater unit to cool down after operation and wear protective gloves. | |
5 | Perform function test of heater |
000 589 13 99 00
Wiring harness repair kit, basic
Powiązane dokumenty
- ar8370s5557e