S83.70-4674-08
1 | Fuel line | 3 | Fuel strainer | |
2 | Union nut | M46/1 | STH fuel metering pump |
Danger ! | Risk of death caused by vehicle slipping or toppling off of the lifting platform. | Align vehicle between vehicle lift columns and position the four support plates at the vehicle lift support points specified by the vehicle manufacturer. | |
Danger ! | Risk of explosion caused by fuel igniting, risk of poisoning caused by inhaling and swallowing fuel as well as risk of injury to eyes and skin caused by contactwith fuel. | No fires, sparks, open flames or smoking. Pour fuels into suitable and appropriately marked containers only. | |
Danger ! | Risk of explosion caused by fuel vapors igniting, risk of poisoning caused by inhaling combustible gases and risk of injury caused by burns during and after operation of heater unit | Do not operate stationary heater, auxiliary heater or engine with heater booster in closed rooms or when refueling. Allow heater unit to cool down after operation and wear protective gloves. | |
| Remove/install | ||
1 | Detach fuel line (1) from stationary heater fuel metering pump (M46/1) | Catch the fuel that leaking in a suitable container; plug the fuel line (1). | |
Record plug | |||
2 | Unscrew union nut (2) | | |
3 | Remove fuel strainer (3) | Installation: If necessary, clean fuel strainer (3). | |
4 | Install in the reverse order | ||
| Check | ||
5 | Perform function test | ||
6 | Inspect fuel system for leaks | Visual inspection only. |
129 589 00 91 00
Record plug
Powiązane dokumenty
- as0000z001001a Zagrożenie życia na skutek ześlizgnięcia lub spadnięcia pojazdu z podnośnika.
- as4700z000101a Niebezpieczeństwo wybuchu wskutek zapalenia, niebezpieczeństwo zatrucia wskutek wdychania i połknięcia paliwa oraz niebezpieczeństwo obrażeń wskutek kontaktu skóry i oczu z paliwem.
- as8370z000201a Niebezpieczeństwo wybuchu oparów paliwa, niebezpieczeństwo zatrucia na skutek wdychania spalin i niebezpieczeństwo zranienia na skutek poparzenia podczas lub po fazie grzania.