AR83.70-P-5302SN | Remove/install heater unit | 14.2.12 |
MODEL 450.3## /4## (except , 450.418) 1# as of 11.2.02 with ENGINE 660.940
with CODE (11Z) Stationary heater
with CODE (LHD) Left-hand drive vehicle
P83.70-4782-06
1 Bolts for diagonal strut
2 Screws for retainer
3 Nuts
4 Circulation pump power supply
5 Hose clamp
6 Coolant hoses
7 Hose clamp on combustion air intake line
8 Heater unit
9 Fuel line
Modification notes
| Remove/install | ||
Danger! | Risk of explosion caused by fuel igniting, risk of poisoning caused by inhaling and swallowing fuel and risk of injury to eyes and skin caused by contact with fuel | No fire, sparks, open flames or smoking. Wear protective clothing when handling fuel. | |
Danger! | Risk of injury to skin and eyes caused by handling hot or glowing objects. | Wear safety gloves, protective clothing and safety glasses, if necessary. | |
Danger! | Risk of injury to skin and eyes caused by scalding from contact with hot coolant spray. Risk of poisoning caused by swallowing coolant. | Do not open cooling system unless coolant temperature is below 90°C. Open cap slowly and release the pressure. Do not pour coolant into beverage containers. Wear protective gloves, protective clothing and safety glasses. | |
1 | Carry out quick test with diagnostic equipment | ||
| Connect STAR DIAGNOSIS and read out fault memory | ||
STAR DIAGNOSIS diagnosis system | |||
2 | Disconnect battery ground line | ||
3 | Drain coolant | ||
4 | Remove underfloor paneling | ||
5.1 | Remove bolts on diagonal strut (1) | Only model 450.4. | |
| |||
6 | Remove bolts of retaining plate (2) | Place a suitable lifting device underneath. | |
7 | Unscrew nuts (3) at EJOT studs from heater (8) | If the heater (8) is replaced, the EJOT studs must be transferred. | |
8 | Disconnect circulation pump power supply (4) | ||
9 | Detach connectors on heater (8) | ||
10 | Release hose clamp (5) at fuel line (9) and disconnect fuel line (9) | Prevent the fuel from escaping with suitable aids. | |
11 | Release hose clamps of coolant hoses (6) at heater (8) and disconnect coolant hoses (6) | Place receptacle underneath. | |
12 | Release clamp at combustion air intake line (7) and disconnect combustion air intake line at heater (8) | If the heater (8) is replaced, the exhaust muffler and EJOT studs of the removed heater (8) must be transferred. | |
13 | Remove heater (8) | ||
14 | Install in the reverse order | ||
15.1 | Remove invalid dates on model plate of heater (8) | Only if the heater (8) was replaced. | |
16 | Treat heater components with corrosion protection wax | ||
17 | Perform function test | ||
18.1 | Print out and fill out form | ||
| Warranty case for stationary heater checklist, form | * For Germany only |
Diagonal strut to underbody
Powiązane dokumenty
- ad0000p200004sm
- ar2000p1142sm
- ar2000p1142smg Spuść, napełnij układ płynem chłodzącym.
- ar5410p0003sm
- ar6130p1001sm
- ar8370p2028sm
- as0000z000201a Niebezpieczeństwo zranienia skóry i oczy na skutek kontaktu z gorącymi lub żarzącymi się przedmiotami
- as2000z000101a Niebezpieczeństwo zranienia skóry i oczu przez poparzenie wytryskującym, gorącympłynem chłodzącym. Niebezpieczeństwo zatrucia na skutek połknięcia płynu chłodzącego
- as4700z000101a Niebezpieczeństwo wybuchu wskutek zapalenia, niebezpieczeństwo zatrucia wskutek wdychania i połknięcia paliwa oraz niebezpieczeństwo obrażeń wskutek kontaktu skóry i oczu z paliwem.
- of8370p300003a Reklamacja gwarancyjna na ogrzewanie postojowe - lista kontroli, formularz