AR83.55-D-5300NB | Remove/install refrigerant compressor | 26.3.04 |
MODEL WD1, WD2, WD3, WD6, WD7, XD1, XD2, XD3, XD4, XD5, XD6, XD7, YD1, YD2, YD3, YD4, YD5, YD6, YD7 with ENGINE 647.981
MODEL 903.61 /66 /67, 904.61 /66 with ENGINE 647.981 with CODE (ZU7) National version for Canada
MODEL 903.61 /66 /67, 904.61 /66 with ENGINE 647.981 with CODE (ZU8) National version for USA
MODEL 903.61 /62 /66 /67, 904.61 /62 /66 with ENGINE 647.981 with CODE (ZU9) National version for Mexico
D83.55-1101-06
1 Refrigerant compressor
2 Refrigerant line
3 Refrigerant line
4 Sealing ring
5 Sealing ring
6 Bolt
7 Bolt
8 Bracket
9 Bolt
10 Electrical connector
| Remove/install | ||
Danger! | Risk of explosion from welding or soldering work on closed air conditioning system. Risk of poisoning from inhaling overheated refrigerant vapors. Risk of injury to skin and eyes caused by contact with liquid refrigerant. | Never perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear safety glasses and protective gloves. Work only in well ventilated areas. Carry out repair work on the air conditioning system circuit only after the system has been discharged. | |
1 | Discharge air conditioning system | ||
| Protect air conditioning circuit and components from moisture when carrying out repair work | All models fitted with air conditioning | |
2 | Remove poly-V-belt | ||
3 | Disconnect electrical connector (10) from AC compressor (1) | Installation: Ensure that electrical connector (10) is seated properly. | |
4 | Detach refrigerant lines (2, 3) on refrigerant compressor (1) | Installation: Replace sealing rings (4, 5). | |
| |||
5 | Unscrew screws (9) and remove AC compressor (1) | | |
6.1 | Replace refrigerant lines (2, 3) and expansion valve | Only if the refrigerant compressor (1) is replaced because of an internal fault. | |
7 | Install in the reverse order | ||
8 | Evacuate the air conditioning system, refill it, and then check the system to make sure that it functions correctly and does not leak. |
Refrigerant lines
Number | Designation | Models | Models | Models | |
BA83.30-N-1009-02A | Screw for refrigerant line on refrigerant compressor | Nm | 21 (2 ) | 21 (2 ) | 21 (2 ) |
Refrigerant compressor
Number | Designation | Model | Models | Models | |
BA83.55-N-1001-01B | Bolt, refrigerant compressor/bracket | Nm | 20 | 20 | 20 |
Powiązane dokumenty
- ah8330n000501a Ochrona obwodu i elementów układu klimatyzacji przed wilgocią podczas napraw
- ar1322d1202nb
- ar8330d1760a Opróżnianie, wytwarzanie próżni, ponowne napełnianie, sprawdzanie działania i szczelności układu klimatyzacji
- as8300z000101a Niebezpieczeństwo wybuchu na skutek prac spawalniczych lub lutowniczych na zamkniętym układzie klimatyzacji. Niebezpieczeństwo zatrucia na skutek wdychania przegrzanych oparów czynnika chłodzącego. Niebezpieczeństwo obrażeń na sk