AR83.55-D-5300NA | Remove/install refrigerant compressor | 15.12.09 |
MODEL WD1XD141, WD1XD241, WD1XD341, WD1XD441, WD1XD541, WD1XD641, WD1XD741,
WD2YD141, WD2YD241, WD2YD341, WD2YD441, WD2YD541, WD2YD641, WD2YD741,
WD5WD141, WD5WD241, WD5WD341, WD5WD641, WD5WD741
with ENGINE 612.981
MODEL 903.61 /66 /67, 904.61 /66 with ENGINE 612.981 with CODE (ZU7) National version for Canada
MODEL 903.61 /66 /67, 904.61 /66 with ENGINE 612.981 with CODE (ZU8) National version for USA
MODEL 903.61 /66 /67, 904.61 /66 with ENGINE 612.981 with CODE (ZU9) National version for Mexico
D83.55-1101-06
1 Refrigerant compressor
2 Refrigerant line intake side
3 Refrigerant line pressure side
4 Sealing ring
5 Sealing ring
6 Screw
7 Screw
8 Bracket
9 Screw
10 Electrical connector
| Remove/install | ||
Danger! | Risk of explosion caused by welding or soldering work on closed air conditioning system. Risk of poisoning caused by inhaling overheated refrigerant vapors. Risk of injury to skin and eyes caused by contact with liquid refrigerant. | Never perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear safety glasses and protective gloves. Work only in well ventilated areas. Carry out repair work on the air conditioning system circuit only after the system has been discharged. | |
| Protect air conditioning circuit and components from moisture when carrying out repair work | All models with air conditioning | |
1 | Discharge air conditioning system | ||
2 | Release poly-V belt and remove AC compressor (1) | ||
3 | Disconnect electrical connector (10) from AC compressor (1) | ||
4 | Remove refrigerant lines (2, 3) from AC compressor | Installation: Replace sealing rings (4, 5). | |
| |||
5 | Unscrew screws (9) and remove AC compressor (1) |
Installation: top up compressor oil. | |
| |||
6 | Install in the reverse order | If refrigerant compressor had to be replaced because of internal fault | |
Install new connecting lines (2, 3) with sealing rings. | |||
replace expansion valve. | |||
7 | Evacuate the air conditioning system, refill it, and then check the system to make sure that it functions correctly and does not leak. |
Refrigerant lines
Number | Designation | Model | Model | Model | |
BA83.30-N-1009-02A | Bolt for refrigerant line on refrigerant compressor | Nm | 21 (2) | 21 (2) | 21 (2) |
Refrigerant compressor
Number | Designation | Model | Model | Model | |
BA83.55-N-1001-01B | Bolt, refrigerant compressor/bracket | Nm | 20 | 20 | 20 |