1 | Low pressure switch |
M83.50-0045-11
| Remove/install | ||
Danger | Risk of explosion caused by welding or soldering work on closed air conditioning system. Risk of poisoning caused by inhaling overheated refrigerant vapors. Risk of injury to skin and eyes caused by contact with liquid refrigerant. | Never perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear safety glasses and protective gloves. Work only in well ventilated areas. Carry out repair work on the air conditioning system circuit only after the system has been drained. | |
Topical note | Protect air conditioning circuit and components from moisture when carrying out repair work | ||
Topical note | Procedure for a damaged or leaky air conditioning system | ||
Notes on handling refrigerant R134a | |||
1 | Drain air conditioning system | ||
2 | Disconnect connector couplings and remove low-pressure switch (1) | ||
| |||
Seal off opening. | |||
Installation: Replace seal. Coat sealing ring with compressor oil before installation. | |||
Pressure switch to refrigerant line | |||
Record plug | |||
3 | Install in the reverse order | ||
4 | Replace air conditioning system filter drier | ||
5 | Evacuate air conditioning system, charge it, and then check system to make sure that it functions correctly and does not leak |
129 589 00 91 00
Record plug
Powiązane dokumenty
- ah8330n000301a Wskazówki dotyczące postępowania z czynnikiem chłodzącym R134a
- ah8330n000401a Postępowanie przy uszkodzonym lub nieszczelnym układzie klimatyzacji
- ah8330n000501a Ochrona obwodu i elementów układu klimatyzacji przed wilgocią podczas napraw
- ar8330m1760d
- ar8350m5090d
- as8300z000101a Niebezpieczeństwo wybuchu na skutek prac spawalniczych lub lutowniczych na zamkniętym układzie klimatyzacji. Niebezpieczeństwo zatrucia na skutek wdychania przegrzanych oparów czynnika chłodzącego. Niebezpieczeństwo obrażeń na sk
- bb0040p036200a Oleje do sprężarek (specyfikacja 362.0)