M83.50-0051-08
1 | Union nut | 2 | Inspection glass | 3 | Filter drier |
| Remove/install | ||
Danger | Risk of death caused by falling from vehicle roof. Risk of injury to other persons caused by falling objects during work in roof area. | ||
Danger | Risk of explosion caused by welding or soldering work on closed air conditioning system. Risk of poisoning caused by inhaling overheated refrigerant vapors. Risk of injury to skin and eyes caused by contact with liquid refrigerant. | Never perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear safety glasses and protective gloves. Work only in well ventilated areas. Carry out repair work on the air conditioning system circuit only after the system has been drained. | |
Topical note | Protect air conditioning circuit and components from moisture when carrying out repair work | ||
Topical note | Procedure for a damaged or leaky air conditioning system | ||
Notes on handling refrigerant R134a | |||
1 | Drain air conditioning system | ||
2 | Open air conditioning system cover | ||
3 | Unscrew union nuts (1) | ||
| |||
Plug openings. | |||
Installation: Install new sealing rings. Coat sealing rings with compressor oil before installation. | |||
Line connection to filter drier | |||
Line connection to inspection glass | |||
Record plug | |||
4 | Release mounting clamp and remove filter drier (3) with inspection glass (2) | Bolt, mounting clamp of filter drier | |
5 | Unscrew inspection glass (2) from filter drier (3) | ||
| |||
Determine remaining quantity of compressor oil in removed filter drier (3). Fill same amount of new compressor oil into new filter drier (3). Observe arrow marking for flow direction of filter drier (3). | |||
6 | Install in the reverse order | Seal air conditioning system cover only after charging and checking air conditioning system. | |
7 | Evacuate air conditioning system, refill it, and then check the system to make sure that it functions correctly and does not leak |
129 589 00 91 00
Record plug
Powiązane dokumenty
- ah8330n000301a Wskazówki dotyczące postępowania z czynnikiem chłodzącym R134a
- ah8330n000401a Postępowanie przy uszkodzonym lub nieszczelnym układzie klimatyzacji
- ah8330n000501a Ochrona obwodu i elementów układu klimatyzacji przed wilgocią podczas napraw
- ar8330m1760d
- ar8350m5017d
- as6500z000201a Zagrożenie życia na skutek spadnięcia z dachu pojazdu. Niebezpieczeństwo obrażeńprzez inne osoby, spowodowane przez przedmioty spadające podczas wykonywania prac w obszarze dachu
- as8300z000101a Niebezpieczeństwo wybuchu na skutek prac spawalniczych lub lutowniczych na zamkniętym układzie klimatyzacji. Niebezpieczeństwo zatrucia na skutek wdychania przegrzanych oparów czynnika chłodzącego. Niebezpieczeństwo obrażeń na sk
- bb0040p036200a Oleje do sprężarek (specyfikacja 362.0)