D83.50-1343-08
1 | Cross bow | E | Refrigerant line (pressure side) | ||||
2 | Nut | L | Refrigerant line (intake side) |
D83.50-1344-08
3 | Screw | S | Refrigerant line (pressure side) | ||||
R | Refrigerant line (pressure side) | T | Refrigerant line (intake side) |
D83.50-1345-08
4 | Expansion valve | 7 | Bracket | R | Refrigerant line (pressure side) | ||
5 | Expansion valve | 8 | Screw | S | Refrigerant line (pressure side) | ||
6 | Screw | 9 | Bracket | T | Refrigerant line (intake side) |
D83.50-1346-08
5 | Expansion valve | L | Refrigerant line (intake side) | T | Refrigerant line (intake side) | ||
10 | Sealing ring | R | Refrigerant line (pressure side) | ||||
11 | Sealing ring | S | Refrigerant line (pressure side) |
Danger ! | Risk of explosion caused by welding or soldering work on closed air conditioning system. Risk of poisoning caused by inhaling overheated refrigerant vapors. Risk of injury to skin and eyes caused by contact with liquid refrigerant. | Never perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear safety glasses and protective gloves. Work only in well-ventilated areas. Carry out repair work on the air conditioning system circuit only after the system has been drained. | |
Danger ! | Risk of death caused by falling from vehicle roof. Risk of injury to other persons caused by falling objects during work in roof area. | ||
| Protect air conditioning circuit and components from moisture when carrying out repair work | ||
| Procedure for a damaged or leaky air conditioning system | All models | |
| Notes on handling refrigerant R134a | ||
| Remove/install | ||
1 | Drain air conditioning system | MODEL 900 | |
MODEL 900.633/65 | |||
Installation: Evacuate air conditioning system, charge it and then check system for proper operation and for leaks. | |||
2 | Remove headliner | ||
Installation: Mount headliner only after charging and checking air conditioning system. | |||
3 | Unscrew nut (2) | ||
4 | Remove roof air conditioning cover | ||
Installation: Mount cover for roof air conditioning only after charging and checking the air conditioning system. | |||
5 | Remove bitumen insulation tape in area of connecting point for refrigerant line (T) to passenger compartment (arrows) | Installation: Carefully wrap new bitumen insulation tape around the area surrounding the connecting point of the refrigerant line (T) to the passenger compartment (arrows). | |
Insulation | |||
6 | Unscrew screw/bolt (3) | ||
7 | Remove bitumen insulation tape over expansion valves (4 and 5) | Installation: Carefully wrap new bitumen insulation tape around area surrounding expansion valves (4 and 5). | |
Insulation | |||
8 | Unscrew screw/bolt (6) and remove bracket (7) | ||
9 | Unscrew screw/bolt (8) and remove bracket (9) | ||
10 | Remove refrigerant line (T) | Installation: Mount refrigerant line (T) with new sealing rings (11). Replace sealing rings of refrigerant line (S) at expansion valves (4 and 5) and sealing ring (10) of refrigerant line (L). | |
11 | Close off openings of refrigerant line (T), expansion valves (4 and 5) and refrigerant line (L) using stop plugs | Record plug | |
12 | Replace fluid reservoir | ||
After completing the work at the open refrigerant circuit, the accumulator must be replaced. | |||
13 | Install in the reverse order |
129 589 00 91 00
Record plug
Powiązane dokumenty
- ah8330n000301a Wskazówki dotyczące postępowania z czynnikiem chłodzącym R134a
- ah8330n000401a Postępowanie przy uszkodzonym lub nieszczelnym układzie klimatyzacji
- ah8330n000501a Ochrona obwodu i elementów układu klimatyzacji przed wilgocią podczas napraw
- ar6830d4300ch
- ar8330d1300ch
- ar8330d1760we Opróżnianie, wytwarzanie próżni, ponowne napełnianie, sprawdzanie działania i szczelność układu klimatyzacji
- ar8350d5080ch
- as6500z000201a Zagrożenie życia na skutek spadnięcia z dachu pojazdu. Niebezpieczeństwo obrażeńprzez inne osoby, spowodowane przez przedmioty spadające podczas wykonywania prac w obszarze dachu
- as8300z000101a Niebezpieczeństwo wybuchu na skutek prac spawalniczych lub lutowniczych na zamkniętym układzie klimatyzacji. Niebezpieczeństwo zatrucia na skutek wdychania przegrzanych oparów czynnika chłodzącego. Niebezpieczeństwo obrażeń na sk