AR83.50-D-6700CH | Remove/install refrigerant lines in underfloor/engine compartment | 18.7.11 |
MODEL 900 with CODE (HK4) Rear air conditioning, reinforced
D83.50-1308-06
A Refrigerant line (pressure side)
B Refrigerant line (pressure side)
O Refrigerant line (intake side)
P Refrigerant line (intake side)
| Remove/install | ||
Danger! | Risk of explosion caused by welding or soldering work on closed air conditioning system. Risk of poisoning caused by inhaling overheated refrigerant vapors. Risk of injury to skin and eyes caused by contact with liquid refrigerant. | Never perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear safety glasses and protective gloves. Work only in well ventilated areas. Carry out repair work on the air conditioning system circuit only after the system has been drained. | |
| Procedure for a damaged or leaky air conditioning system | ||
| Protect air conditioning circuit and components from moisture when carrying out repair work | ||
| Notes on handling R134a refrigerant | Air conditioning with refrigerant R134a | |
1 | Drain air conditioning system | Installation: Evacuate, refill and check air conditioner for proper operation and leaks | |
2 | Lift/jack up vehicle | ||
3 | Expose damaged refrigerant line (A, B, O, or P) | Installation: Check brackets and threaded connections for damage, replace if necessary. | |
4 | Remove refrigerant line (A, B, O, or P) | Installation: Mount refrigerant line (A, B, O or P) with new sealing rings. Coat sealing rings with compressor oil. | |
Screw/bolt, refrigerant line to refrigerant compressor | |||
| Compressor oils | Sheet 362.0 | |
5 | Close off each opening of refrigerant lines (A, B, O or P), interior refrigerant lines and of refrigerant compressor with stop plugs | Set of stop plugs | |
6 | Replace fluid reservoir | After completing the work at the open refrigerant circuit, the accumulator must be replaced. | |
7 | Install in the reverse order |
Air conditioning system
Number | Designation | Model | ||
BA83.30-N-1010-01F | Screw/bolt, refrigerant line to refrigerant compressor | Nm | 22 | |
Set of stop plugs
129 589 00 91 00
Powiązane dokumenty
- ah8330n000301a Wskazówki dotyczące postępowania z czynnikiem chłodzącym R134a
- ah8330n000401a Postępowanie przy uszkodzonym lub nieszczelnym układzie klimatyzacji
- ah8330n000501a Ochrona obwodu i elementów układu klimatyzacji przed wilgocią podczas napraw
- ar0060d1000h Unoszenie pojazdu, podpieranie
- ar8330d1760we Opróżnianie, wytwarzanie próżni, ponowne napełnianie, sprawdzanie działania i szczelność układu klimatyzacji
- ar8350d5080ch
- as8300z000101a Niebezpieczeństwo wybuchu na skutek prac spawalniczych lub lutowniczych na zamkniętym układzie klimatyzacji. Niebezpieczeństwo zatrucia na skutek wdychania przegrzanych oparów czynnika chłodzącego. Niebezpieczeństwo obrażeń na sk
- bb0040p036200a Oleje do sprężarek (specyfikacja 362.0)