D83.50-1336-09
1 | AC housing | 4 | Passage | 7 | Bracket | ||
2 | Condenser | 5 | Fluid reservoir | 8 | Separation point | ||
3 | Union nut | 6 | Screw | Q | Refrigerant line (pressure side) |
D83.50-1337-08
1 | AC housing | 5 | Fluid reservoir | Q | Refrigerant line (pressure side) | ||
3 | Union nut | 9 | Sealing ring | ||||
4 | Passage | 10 | Sealing ring |
Danger | Risk of explosion caused by welding or soldering work on closed air conditioning system. Risk of poisoning caused by inhaling overheated refrigerant vapors. Risk of injury to skin and eyes caused by contact with liquid refrigerant. | Never perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear safety glasses and protective gloves. Work only in well ventilated areas. Carry out repair work on the air conditioning system circuit only after the system has been drained. | |
Danger | Risk of death caused by falling from vehicle roof. Risk of injury to other persons caused by falling objects during work in roof area. | ||
Topical note | Protect air conditioning circuit and components from moisture when carrying out repair work | ||
Topical note | Procedure for a damaged or leaky air conditioning system | ||
Notes on handling refrigerant R134a | |||
| Remove/install | ||
1 | Drain air conditioning system | Model 900 | |
Model 900.633/65 | |||
Installation: Evacuate air conditioning system, charge it and then check system for proper operation and for leaks. | |||
2 | Remove roof air conditioning cover | ||
Installation: Mount cover for roof air conditioning only after charging and checking the air conditioning system. | |||
3 | Remove condenser fan of roof air conditioning | ||
4 | Unscrew union nut (3) | ||
5 | Unscrew bolt (6) and remove bracket (7) | ||
6 | Remove duct (4) from air conditioner housing (1) | Installation: Coat duct (4) with lubricant. | |
Grease, silicone-based, 100 g | |||
7 | Remove refrigerant line (Q) and guide out of air conditioner housing (1) | ||
| Compressor oils (specification 362.0) | ||
Installation: Mount refrigerant line (Q) with new sealing rings (9 and 10). Replace sealing ring of refrigerant line at connecting point (8). | |||
8 | Close off openings of refrigerant line (Q), fluid reservoir (5) and connecting point (8) using stop plugs | Record plug | |
9 | Replace fluid reservoir | ||
After completing the work at the open refrigerant circuit, the accumulator must be replaced. | |||
10 | Install in the reverse order |
129 589 00 91 00
Record plug
Powiązane dokumenty
- ah8330n000301a Wskazówki dotyczące postępowania z czynnikiem chłodzącym R134a
- ah8330n000401a Postępowanie przy uszkodzonym lub nieszczelnym układzie klimatyzacji
- ah8330n000501a Ochrona obwodu i elementów układu klimatyzacji przed wilgocią podczas napraw
- ar8330d1300ch
- ar8330d1760we Opróżnianie, wytwarzanie próżni, ponowne napełnianie, sprawdzanie działania i szczelność układu klimatyzacji
- ar8350d5060ch
- ar8350d5080ch
- as6500z000201a Zagrożenie życia na skutek spadnięcia z dachu pojazdu. Niebezpieczeństwo obrażeńprzez inne osoby, spowodowane przez przedmioty spadające podczas wykonywania prac w obszarze dachu
- as8300z000101a Niebezpieczeństwo wybuchu na skutek prac spawalniczych lub lutowniczych na zamkniętym układzie klimatyzacji. Niebezpieczeństwo zatrucia na skutek wdychania przegrzanych oparów czynnika chłodzącego. Niebezpieczeństwo obrażeń na sk
- bb0040p036200a Oleje do sprężarek (specyfikacja 362.0)