D83.50-1425-78
1 | Caps | 2 | Test and filler connection for high-pressure line | 3 | Test and filler connection for low-pressure line |
Danger | Risk of fire due to ignition of R1234yf refrigerant on hot components. Risk of poisoning caused by inhaling overheated refrigerant vapors. Risk of injury to skin and eyes caused by contact with escaped R1234yf refrigerant and when working on pressurized parts. Risk of explosion due to formation of ignitable refrigerant/air mixtures | Never perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear safety glasses and protective gloves. Work only in well ventilated rooms. Carry out repair work on the air conditioning system circuit only after the system has been evacuated. | |
Warning | Risk of poisoning caused by inhaling overheated refrigerant vapors from an air conditioning system containing R134a. Risk of injury to skin and eyes caused by contact with liquid R134a refrigerant and when working on pressurized parts | Never perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear safety glasses and protective gloves. Work only in well ventilated rooms. Carry out repair work on the air conditioning system circuit only after the system has been evacuated. | |
Topical note | Procedure for a damaged or leaky air conditioning system | ||
Topical note | Protect air conditioning circuit and components from moisture when carrying out repair work | ||
Notes on handling refrigerant R1234yf | |||
Notes on handling refrigerant R134a | |||
Draining | |||
1 | Unscrew covers (1) on test and filler connection for the high-pressure line (2) and the test and filler connection for the low-pressure line (3), and connect the corresponding air conditioning service unit. | ||
| 000 588 10 82 00 R1234yf air conditioning service unit | ||
| 000 588 04 82 00 Air conditioning service unit R134a | ||
Depending on the vehicle's intended purpose, various refrigerants are used to comply with the respective, country-specific legal regulations. | |||
When connecting and when operating the air conditioning service unit, the complete work procedure must be conducted in accordance with the air conditioning service unit manufacturer's operator's manual. | |||
2 | Analyze the refrigerant in the roof-mounted air conditioning system. | Model 907.6/7 with code HX1 (R-1234yf refrigerant) | |
The refrigerant analysis must be performed using an analysis device integrated into the air conditioning service unit or an external analysis device with data transfer to the air conditioning service unit. | |||
A positive gas analysis is given when the refrigerant exhibits a degree of purity of min.98,5 %. | |||
If the gas analysis is positive, | |||
| |||
extract refrigerant from air conditioning system into internal container of air conditioning service unit. | |||
If the gas analysis is negative, | |||
| |||
the gas analysis must be performed up to three times. After a third negative gas analysis, the analysis device must be verified in accordance with the operator's manual. | |||
If the analysis device is functional and the gas analysis is negative, | |||
| |||
extract contaminated refrigerant from air conditioning system into a recycling cylinder. | |||
3 | Drain roof A/C system. | The extracted quantity of compressor oil must be noted down. | |
| Check | ||
4 | Check the refrigerant reservoir of the roof-mounted air conditioning system for re-usability. | ||
Topical note | Protect air conditioning circuit and components from moisture when carrying out repair work | ||
In the case of a corresponding finding, | |||
| |||
Replace the fluid reservoir. | |||
Evacuate | |||
5 | Use the air conditioning service unit to clean the refrigerant and evacuate the refrigerant circuit. | ||
6 | Conduct vacuum test using air conditioning service unit. | If the air conditioning service unit shows a fault message, | |
| |||
check roof-mounted air conditioning system for leak tightness. | |||
Filling | |||
7 | Add new compressor oil to the refrigerant circuit according to the oil filling capacity noted during extraction. | ||
| Compressor oils (specification 362.1) | ||
| |||
| |||
| |||
Depending on the repair case, the oil filling quantity may need to be adjusted accordingly. | |||
Total filling capacity of compressor oil in new refrigerant compressor | |||
Total filling capacity of compressor oil in air conditioning system (incl. refrigerant compressor) | |||
Additional quantity of oil to be added when system suddenly looses fluid (e.g. line ruptured) | |||
Additional oil filling quantity after replacing condenser | |||
Additional oil filling quantity after replacing evaporator | |||
Additional oil filling quantity after replacement of suction line | |||
Additional oil filling quantity after replacement of pressure line | |||
Additional oil filling capacity after replacing refrigerant reservoir | |||
Additional oil filling quantity with detectable leakage | |||
Additional oil filling quantity after replacement of complete roof air conditioner | |||
8 | Fill roof-mounted air conditioning system with the corresponding air conditioning service unit. | ||
| Refrigerant (specification 361.1) | Model 907.6/7 with code HX1 (R-1234yf refrigerant) | |
| Refrigerant (specification 361.0) | Model 907.6/7 except code HX1 (R-1234yf refrigerant) | |
Total filling capacity - refrigerant | |||
9 | Conduct pressure test using air conditioning service unit. | If there is a pressure drop during the pressure test, | |
| |||
check roof-mounted air conditioning system for leak tightness. | |||
10 | Disconnect air conditioning service unit and screw covers (1) onto test and filler connection for high-pressure line (2) and the test and filler connection for the low-pressure line (3). | ||
| Check | ||
Warning | Risk of accident from vehicle starting off by itself when engine running. Risk of injury (bruises and burns) resulting from working on the engine while it is being started or when it is running. | Secure vehicle to prevent it from starting off by itself. Wear closed and snug-fitting work clothes. Do not touch hot or rotating parts. | |
11 | Run engine at idle speed for about 4 minutes and check all the component functions which are of relevance for proper operation of the air conditioning system. |
Roof air conditioning |
Number | Designation | Model 907.6/7 | Model 907.6/7 | ||
BF83.50-N-1001-01TSR | Total filling capacity of compressor oil in new refrigerant compressor | Compressor oil | cm3 | 190 | 190 |
Sheet | |||||
Roof air conditioning |
Number | Designation | Model 907.6/7 | Model 907.6/7 | ||
BF83.50-N-1002-01TSR | Total filling capacity of compressor oil in air conditioning system (incl. refrigerant compressor) | Compressor oil | cm3 | 190 | 190 |
Sheet | |||||
Roof air conditioning |
Number | Designation | Model 907.6/7 | Model 907.6/7 | ||
BF83.50-N-1003-01TSR | Additional quantity of oil to be added when system suddenly looses fluid (e.g. line ruptured) | Compressor oil | cm3 | 65 | 65 |
Sheet | |||||
Roof air conditioning |
Number | Designation | Model 907.6/7 | Model 907.6/7 | ||
BF83.50-N-1004-01TSR | Additional oil filling quantity after replacing condenser | Compressor oil | cm3 | 20 | 20 |
Sheet | |||||
Roof air conditioning |
Number | Designation | Model 907.6/7 | Model 907.6/7 | ||
BF83.50-N-1005-01TSR | Additional oil filling quantity after replacing evaporator | Compressor oil | cm3 | 40 | 40 |
Sheet | |||||
Roof air conditioning |
Number | Designation | Model 907.6/7 | Model 907.6/7 | ||
BF83.50-N-1006-01TSR | Additional oil filling quantity after replacement of suction line | Compressor oil | cm3 | 10 | 10 |
Sheet | |||||
Roof air conditioning |
Number | Designation | Model 907.6/7 | Model 907.6/7 | ||
BF83.50-N-1007-01TSR | Additional oil filling quantity after replacement of pressure line | Compressor oil | cm3 | 10 | 10 |
Sheet | |||||
Roof air conditioning |
Number | Designation | Model 907.6/7 | Model 907.6/7 | ||
BF83.50-N-1008-01TSR | Additional oil filling capacity after replacing refrigerant reservoir | Compressor oil | cm3 | 20 | 20 |
Sheet | |||||
Roof air conditioning |
Number | Designation | Model 907.6/7 | Model 907.6/7 | ||
BF83.50-N-1009-01TSR | Additional oil filling quantity with detectable leakage | Compressor oil | cm3 | 20 | 20 |
Sheet | |||||
Roof air conditioning |
Number | Designation | Model 907.6/7 | Model 907.6/7 | ||
BF83.50-N-1010-01TSR | Additional oil filling quantity after replacement of complete roof air conditioner | Compressor oil | cm3 | 140 | 140 |
Sheet | |||||
Roof air conditioning |
Number | Designation | Model 907.6/7 | Model 907.6/7 | ||
BF83.50-N-1011-01TSR | Total filling capacity - refrigerant | Refrigerant | g | 1100 | 1200 |
Sheet R134a | |||||
Sheet R1234yf | |||||
Powiązane dokumenty
- ah8330n000301a Wskazówki dotyczące postępowania z czynnikiem chłodzącym R134a
- ah8330n000401a Postępowanie przy uszkodzonym lub nieszczelnym układzie klimatyzacji
- ah8330n000501a Ochrona obwodu i elementów układu klimatyzacji przed wilgocią podczas napraw
- ah8330p000302a Wskazówki dotyczące obchodzenia się z czynnikiem chłodzącym R1234yf
- ar8330d1761ts
- ar8350d8020tsr
- as0000z000501a Niebezpieczeństwo wypadku na skutek samoczynnego ruszenia przy pracującym silniku. Niebezpieczeństwo obrażeń na skutek zmiażdżenia lub poparzenia przy wykonywaniu czynności podczas rozruchu lub przy pracującym silniku.
- as8300z000601a Zagrożenie zatruciem na skutek wdychania przegrzanych oparów czynnika chłodzącego R134a. Niebezpieczeństwo obrażeń w przypadku kontaktu płynnego czynnika chłodzącego R134a ze skórą i oczami oraz podczas obchodzenia się z
- as8300z000701a Zagrożenie pożarem na skutek zapłonu czynnika chłodzącego R1234yf przy kontakcie z gorącymi elementami. Niebezpieczeństwo zatrucia na skutek wdychania przegrzanych oparów czynnika chłodzącego. Niebezpieczeństwo obrażeń w przyp
- bb0040p036100a Czynniki chłodzące (specyfikacja 361.0)
- bb0040p036101a Czynniki chłodzące (specyfikacja 361.1)
- bb0040p036101a
- bb0040p036201a
- ws8300p0031b
- ws8300p0034b