Shown on engine 622.9 |
1 | Condenser |
B12 | Refrigerant pressure sensor |
S83.30-4637-04
Shown on engine 622.8 |
1 | Condenser |
2 | Electrical connector |
B12 | Refrigerant pressure sensor |
S83.30-A047-74
Danger | Risk of fire due to ignition of R1234yf refrigerant on hot components. Risk of poisoning caused by inhaling overheated refrigerant vapors. Risk of injury to skin and eyes caused by contact with escaped R1234yf refrigerant and when working on pressurized parts. Risk of explosion due to formation of ignitable refrigerant/air mixtures | Never perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear safety glasses and protective gloves. Work only in well ventilated rooms. Carry out repair work on the air conditioning system circuit only after the system has been evacuated. | |
Warning | Risk of injury. Skin or eye injuries may result when handling hot or glowing objects. | Wear protective gloves, protective clothing and safety glasses, if necessary. | |
Topical note | Procedure for a damaged or leaky air conditioning system | ||
Topical note | Protect air conditioning circuit and components from moisture when carrying out repair work | ||
Topical note | Information on preventing damage to electronic components due to electrostatic discharge | ||
Notes on handling refrigerant R1234yf | |||
| Remove/install | ||
1.1 | Remove condenser (1). | Model 447 with engine 622.9 | |
1.2 | Discharge air conditioning system. | Model 447 with engine 622.8 | |
Model 447 with engine 622.8 | |||
2 | Remove front bumper. | Model 447 with engine 622.8 | |
3 | Release and disconnect electrical connector (2). | Model 447 with engine 622.8 | |
4 | Remove refrigerant pressure sensor (B12). | ||
| Compressor oils (specification 362.1) | ||
Installation: Replace sealing ring and moisten with compressor oil. | |||
Refrigerant pressure sensor to refrigerant condenser or to refrigerant line for refrigerant condenser to refrigerant reservoir | |||
5 | Install in the reverse order |
Powiązane dokumenty
- ah5400p000101a Wskazówki dotyczące zapobiegania uszkodzeniom elementów elektronicznych na skutek rozładowania potencjału elektrostatycznego
- ah8330n000401a Postępowanie przy uszkodzonym lub nieszczelnym układzie klimatyzacji
- ah8330n000501a Ochrona obwodu i elementów układu klimatyzacji przed wilgocią podczas napraw
- ah8330p000302a Wskazówki dotyczące obchodzenia się z czynnikiem chłodzącym R1234yf
- ar8330s1760ef
- ar8330s6540ef
- ar8820s2000e
- as0000z000201a Niebezpieczeństwo zranienia skóry i oczy na skutek kontaktu z gorącymi lub żarzącymi się przedmiotami
- as8300z000701a Zagrożenie pożarem na skutek zapłonu czynnika chłodzącego R1234yf przy kontakcie z gorącymi elementami. Niebezpieczeństwo zatrucia na skutek wdychania przegrzanych oparów czynnika chłodzącego. Niebezpieczeństwo obrażeń w przyp
- bb0040p036201a