AR83.30-P-5253C | Correct oil level in air conditioning system if system is suddenly drained | 15.12.09 |
MODEL 129
with CODE (580) Air conditioning (or Tempmatic for USA)
with CODE (581) Automatic air conditioning
A/C compressor 10PA17
| Perform work rapidly, compressor oil is hygroscopic. During evacuation of refrigerant, add to refrigerant circuit the compressor oil evacuated during recharge of air conditioning (new oil). | ||
1 | Replace defect part and fluid reservoir | on air conditioning system or USA Tempmatic code 580 | |
on air conditioning system code 581a | |||
2 | Add new compressor oil to prescribed oil quantity | ||
3 | Switch on the air conditioner and allow the engine to idle for roughly 4 minutes. | Set temperature selector wheel to blue notches or with automatic air conditioning set to "" Blowers to max. | |
4 | Check air conditioning for proper operation | The air outlet temperature at the center air vent should not drop below approx. + 5 0 C, if necessary |
Refrigerant compressor
Number | Designation | Refrigerant | Refrigerant | ||
BF83.55-P-1002-01A | Additional quantity of oil to be added when system suddenly looses fluid (e.g. line ruptured) | Compressor oil | cm3 | 40 | 40 |
Specifications for Operating Fluids | Sheet | ||||