MODEL | 909 |
with CODE HH9 (Regulated air conditioning (Tempmatic)) |
129 589 00 91 00
Record plug
Remove
1 | Loosen hose clamps (1) and detach coolant hoses (2) from heater housing. |
Collect escaping coolant using suitable vessel. |
Seal openings at heater housing and coolant hoses (2) using suitable stop plugs. |
2 | Unscrew screws (3) and remove connector from refrigerant lines (4). |
Seal openings at heater housing and refrigerant line connector (4) using suitable stop plugs. |
D83.25-1101-01
D83.40-1101-01
Installing
3 | Install refrigerant line (4) connector and check for proper seat. |
Use new O-rings and moisten with compressor oil before installation. |
4 | Tighten screws/bolts (3) evenly by turns . |
5 | Attach coolant hoses (2) and tighten hose clamps (1). |
Inspect hose clamps (1), replace if necessary. |
D83.40-1101-01
D83.25-1101-01