ar8325d100001fa

Remove and install connections from and to front of heater housing

Type ar · topic 83.25 · version 0100 · 2013-06-17

Applies to: MODEL 909 with CODE HH9 (Regulated air conditioning (Tempmatic))

Where it sits

Function group 3 Body › 83 Climate control › 83.25 Automatic heater — Series 909

EinPAS 39 Heating/ventilation/cooling › 39.15 Climate control › 39.15.32 Housing/heat exchanger/evaporator/filter — Series 909

AR83.25-D-1000-01FA

Remove and install connections from and to front of heater housing

MODEL

909

with CODE HH9 (Regulated air conditioning (Tempmatic))

Refrigerant lines

Number

Designation

MODEL 909
with CODE HH9 (Regulated air conditioning (Tempmatic))

BA83.30-N-1008-02A

Screw/bolt, refrigerant line connector block on evaporator

Nm

5 (0,5)

Remove and install connections from and to front of heater housing

129 589 00 91 00

Record plug

Remove and install connections from and to front of heater housing
Remove and install connections from and to front of heater housing

Remove

1

Loosen hose clamps (1) and detach coolant hoses (2) from heater housing.


Collect escaping coolant using suitable vessel.


Seal openings at heater housing and coolant hoses (2) using suitable stop plugs.


2

Unscrew screws (3) and remove connector from refrigerant lines (4).


Seal openings at heater housing and refrigerant line connector (4) using suitable stop plugs.

D83.25-1101-01

D83.40-1101-01

Remove and install connections from and to front of heater housing
Remove and install connections from and to front of heater housing

Installing

3

Install refrigerant line (4) connector and check for proper seat.


Use new O-rings and moisten with compressor oil before installation.


4

Tighten screws/bolts (3) evenly by turns .


5

Attach coolant hoses (2) and tighten hose clamps (1).


Inspect hose clamps (1), replace if necessary.
The threaded connections of the hose clamps (1) must be on the right in the direction of travel.

D83.40-1101-01

D83.25-1101-01