D83.10-1186-09
1 | Bolts | 2 | Air duct |
2 | Air duct |
3 | Bracket |
4 | Fresh air and recirculated air flap |
5 | Bolts |
6 | Switchover valve |
D83.10-1187-06
| Remove/install | ||
1 | Remove ventilation box | ||
2 | Remove bolt (1) | ||
3 | Remove air duct (2) from ventilation box | ||
4 | Unclip the bracket (3) (arrow) and pull out of air duct (2) | Installation: Ensure that the fresh air and air recirculation flap (4) is seated properly in the bracket (3). | |
5 | Unscrew screws/bolts (5) and remove switchover valve (6) | ||
6 | Install in the reverse order |