ar8310d2059f

Removing and installing switchover valve for fresh air flap and recirculated airflap

Type ar · topic 83.10 · version 0100 · 2017-01-16

Applies to: Model 909

Where it sits

Function group 3 Body › 83 Climate control › 83.10 Ventilation — Series 909

EinPAS 39 Heating/ventilation/cooling › 39.15 Climate control › 39.15.13 Line/hose/valve — Series 909

AR83.10-D-2059F

Removing and installing switchover valve for fresh air flap and recirculated airflap

16.12.2016

Model

909

Removing and installing switchover valve for fresh air flap and recirculated    
	airflap

D83.10-1186-09

1

Bolts

2

Air duct

Removing and installing switchover valve for fresh air flap and recirculated    
	airflap

2

Air duct

3

Bracket

4

Fresh air and recirculated air flap

5

Bolts

6

Switchover valve

D83.10-1187-06

Remove/install

1

Remove ventilation box

AR83.10-D-0010F

2

Remove bolt (1)

3

Remove air duct (2) from ventilation box

4

Unclip the bracket (3) (arrow) and pull out of air duct (2)

Installation: Ensure that the fresh air and air recirculation flap (4) is seated properly in the bracket (3).

5

Unscrew screws/bolts (5) and remove switchover valve (6)

6

Install in the reverse order