ar7733p3470r

Adjust Bowden cable for lock on C-pillar

Typ ar · temat 77.33 · wersja 0205 · 2011-09-15

Dotyczy: MODEL 230.4 except CODE (P99) "AMG Black Series" special model

Niedostępne w języku „pl”; wyświetlono w języku Angielski.

Umiejscowienie

Grupa funkcyjna 3 Nadwozie › 77 Okno dachowe, dach składany, nasadki › 77.33 Mechanizm składanego dachu Vario — Seria 230 (modele 4**)

EinPAS 38 System dachu › 38.20 Dach składany/Vario/coupé › 38.20.31 Dach Vario/ dach coupé — Seria 230 (modele 4**)

AR77.33-P-3470R

Adjust Bowden cable for lock on C-pillar

14.9.11

MODEL 230.4 except CODE (P99) "AMG Black Series" special model

Adjust Bowden cable for lock on C-pillar

P77.33-2048-11

Shown on left C-pillar

10 Panel

Adjust Bowden cable for lock on C-pillar

P77.33-2115-09

Shown on left C-pillar

1 Bowden cables

2 Clip-type fastener

3 Wedge slide

4 Emergency unlocking

9 Main guide

A Adjustment dimension for Bowden cable

5 Latch middle piece

6 Pin

7 Mating mount for Bowden cable

8 Mounting wedge

Removing

Danger!

Risk of injury caused by moving parts that can pinch, crush or, in extreme cases, even sever extremities

No parts of the body or limbs should be within the operating range of the mechanism when moving components.

AS00.00-Z-0009-01A

Danger!

Risk of injury caused by body parts being trapped or crushed when working on partially open Vario roof (stop mode) or in its closing area as a result of the Vario roof suddenly collapsing

Secure Vario roof with a suitable special tool.

AS77.50-Z-0001-01A

1

Remove paneling from front Vario roof

AR68.30-P-4350R

2

Remove covering (10) from left and right C-pillar.

3

Completely close Vario roof with Vario roof switch

4

Lock front catch with 6 mm Allen wrench on emergency unlocking (4).

Adjust

5

Remove clip-type fasteners (2) from catch middle piece (5)

6

Press gate valve (3) toward front against stop on bolt (6). Then tighten Bowden cable core (1) and attach clip-type fastener (2)

Press Bowden cable sleeve in direction of arrow with mounting wedge (8). This tensions the core of the Bowden cable (1).

*110589035900

7

Lock and unlock Vario roof a number of times with a 6 mm Allen wrench on emergency unlocking (4) on catch center section (5).

The gate valve (3) is completely open when the front catch is unlocked.

8

Check adjustment dimension of Bowden cable (A), repeat adjustment if necessary

With gate valve (3) completely open

*BE77.33-P-1004-01A

9

Lock front catch with 6 mm Allen wrench on emergency unlocking (4).

10

Move Vario roof to intermediate position with Vario roof switch and secure.

While opening the Vario roof, check whether the tip of the gate valve (3) touches the cam on the main guide (9).

If so, repeat adjustment.

AR77.50-P-3000-01R

*230589046300

Install

11

Install cover (10) on left and right C-pillar

Insert mounting wedge (8) between covering (10) and gate valve (3) to prevent pulling covering (10) to gate valve (3).

*110589035900

12

Install paneling at front of Vario-roof

AR68.30-P-4350R

Test values for Vario roof and soft top mechanism

Number

Designation

Model 230

BE77.33-P-1004-01A

Adjustment dimension for Bowden cable

mm

1 to 2

Adjust Bowden cable for lock on C-pillar
Adjust Bowden cable for lock on C-pillar

230 589 04 63 00

Support

Mounting wedge

110 589 03 59 00

Powiązane dokumenty