AR77.33-P-3470R | Adjust Bowden cable for lock on C-pillar | 14.9.11 |
MODEL 230.4 except CODE (P99) "AMG Black Series" special model
P77.33-2048-11
Shown on left C-pillar
10 Panel
P77.33-2115-09
Shown on left C-pillar
1 Bowden cables
2 Clip-type fastener
3 Wedge slide
4 Emergency unlocking
9 Main guide
A Adjustment dimension for Bowden cable
5 Latch middle piece
6 Pin
7 Mating mount for Bowden cable
8 Mounting wedge
| Removing | ||
Danger! | Risk of injury caused by moving parts that can pinch, crush or, in extreme cases, even sever extremities | No parts of the body or limbs should be within the operating range of the mechanism when moving components. | |
Danger! | Risk of injury caused by body parts being trapped or crushed when working on partially open Vario roof (stop mode) or in its closing area as a result of the Vario roof suddenly collapsing | Secure Vario roof with a suitable special tool. | |
1 | Remove paneling from front Vario roof | ||
2 | Remove covering (10) from left and right C-pillar. | ||
3 | Completely close Vario roof with Vario roof switch | ||
4 | Lock front catch with 6 mm Allen wrench on emergency unlocking (4). | ||
Adjust | |||
5 | Remove clip-type fasteners (2) from catch middle piece (5) | ||
6 | Press gate valve (3) toward front against stop on bolt (6). Then tighten Bowden cable core (1) and attach clip-type fastener (2) | Press Bowden cable sleeve in direction of arrow with mounting wedge (8). This tensions the core of the Bowden cable (1). | |
| |||
7 | Lock and unlock Vario roof a number of times with a 6 mm Allen wrench on emergency unlocking (4) on catch center section (5). | The gate valve (3) is completely open when the front catch is unlocked. | |
8 | Check adjustment dimension of Bowden cable (A), repeat adjustment if necessary | With gate valve (3) completely open | |
9 | Lock front catch with 6 mm Allen wrench on emergency unlocking (4). | ||
10 | Move Vario roof to intermediate position with Vario roof switch and secure. | While opening the Vario roof, check whether the tip of the gate valve (3) touches the cam on the main guide (9). If so, repeat adjustment. | |
| |||
| Install | ||
11 | Install cover (10) on left and right C-pillar | Insert mounting wedge (8) between covering (10) and gate valve (3) to prevent pulling covering (10) to gate valve (3). | |
| |||
12 | Install paneling at front of Vario-roof |
Test values for Vario roof and soft top mechanism
230 589 04 63 00
Support
Mounting wedge
110 589 03 59 00