ar7720p1999tx

Remove/install water drain channel on tilting/sliding roof

Typ ar · temat 77.20 · wersja 0100 · 2006-07-26

Dotyczy: MODEL 219.3 with CODE (414) Glass electric tilting/sliding roof

Niedostępne w języku „pl”; wyświetlono w języku Angielski.

Umiejscowienie

Grupa funkcyjna 3 Nadwozie › 77 Okno dachowe, dach składany, nasadki › 77.20 Okno dachowe przesuwane elektrycznie — Seria 219 (modele 3**)

EinPAS 38 System dachu › 38.15 Okno dachowe przesuwne/ panoramiczne okno dachowe przesuwne › 38.15.32 Roleta/ kaseta/ okładzina — Seria 219 (modele 3**)

AR77.20-P-1999TX

Remove/install water drain channel on tilting/sliding roof

12.8.04

MODEL 219.3 with CODE (414) Glass electric tilting/sliding roof

Remove/install water drain channel on tilting/sliding roof

P77.20-2497-09

1 Water drain channel

2 Sliding roof lining

3 Covering

7 Long wedge

8 Tilting bracket

4 Tilting/sliding roof cover

5 Rubber bellows

6 Mounting wedge

Remove/Install

Danger!

Risk of injury caused by fingers being jammed or pinched when removing, installing or aligning hoods, doors, trunk lid/rear-end door or sliding roof.

When moving components, ensure that no body parts or limbs are within the operating range of moving parts.

AS00.00-Z-0011-01A

1

Completely open sliding roof lining (2)

2

Open tilting/sliding roof cover (4) approx. 20 cm

3

Unclip covering (3) in center and on side with mounting wedge (6), move covering (3) out of rubber bellows (5)

*110589035900

Installation: Position covering (3) in center and clip in. Arrest catch hooks for covering (3) in center and into both rubber bellows (5)

4

Completely close tilting/sliding roof cover (4) and then move tilting/sliding roof (4) to pop-up position

5

Remove left and right rubber bellows (5) from tilting/sliding roof cover (4)

Carefully pull rubber bellows (5) up and down to prevent damage

Observe installation position of rubber bellows (5)

6

Unclip water drain channel (1) from left and right brackets on pop-up bracket (8) with long wedge (7)

*115589035900

7

Slide water drain channel (1) on passenger side in between sliding sunroof lining (2) and roof paneling, pull out on driver's side and remove.

8

Install in the reverse order

9

Perform teach-in run for tilting/sliding roof obstruction sensor

Connect STAR DIAGNOSIS and read out fault memory

AD00.00-P-2000-04A

Diagnosis system STAR DIAGNOSIS

*WH58.30-Z-1048-13A

Remove/install water drain channel on tilting/sliding roof
Remove/install water drain channel on tilting/sliding roof

115 589 03 59 00

Long wedge

Mounting wedge

110 589 03 59 00

Commercially available tools

Number

Designation

WH58.30-Z-1048-13A

STAR DIAGNOSIS diagnosis system, Compact Passenger Car

6511 1801 00

Powiązane dokumenty