P72.10-2787-06
1 Front door
2 Bolts
3 Assembly stop
Adjust | |||
1 | Remove front CBS | ||
2 | Remove paneling in footwell. | ||
3 | Remove assembly stop (3) | Mark installation position for assembly stop (3) | |
4 | Loosen bolts (2) from A-pillar | ||
5 | Checks gaps on front door and adjust if necessary | Gaps on hoods, doors and lids | |
Model 452.3 | |||
Model 452.4 | |||
Feeler gauge | |||
6 | Tighten bolts (2) on A-pillar | | |
7 | Install paneling in footwell | ||
8 | Install assembly stop (3) | Observe markings | |
9 | Install front CBS |
Test and adjustment values for gap dimensions
Number | Designation | Model | Model | |||
BE60.00-P-1002-01J | Gap dimension | Front door to front fender | Dimension "D" | mm | 6.0 (1.5) | 6.0 (1.5) |
Rolldown window to side stay/hard top | Dimension "E" | mm | 9.0 (2.0) | 9.0 (2.0) | ||
Front door to bottom side wall | Dimension "F" | mm | 7.0 (2.0) | 7.0 (2.0) | ||
Front door to rear side wall | Dimension "G" | mm | 8.0 (2.0) | 8.0 (2.0) | ||
Front door paneling to A-pillar | Dimension "H" | mm | 5.0 (1.5) | 5.0 (1.5) | ||
Front door
Feeler gauge
129 589 03 21 00