S60.00-4851-06
1 | Bracket |
3 | Electrical wiring harness |
S60.00-A049-06
Danger | Risk of death when working on component parts and systems with U >= 30 V alternating voltage (AC) or U >= 60 V direct voltage (DC) | Do not touch damaged or defective live component parts and lines or non-insulated electrical connections and lines. | |
Danger | Risk of death caused by vehicle slipping or toppling off of the lifting platform. | Align vehicle between vehicle lift columns and position the four support plates at the vehicle lift support points specified by the vehicle manufacturer. | |
Topical note | General information on vehicles with high-voltage on-board electrical system and/or lithium-ion battery and/or gaseous-fuel drive system as well as personal protective equipment | ||
Topical note | Special instructions for lifting and supporting vehicle | ||
| Remove/install | ||
1 | Remove front-end assembly. | ||
2 | Remove radiator unit. | ||
3 | Remove front crash box. | ||
4 | Remove electric coolant pump for electric motor cooling. | ||
5 | Remove fender liner in left fender. | ||
6 | Remove electrical wiring harness (3) and place outside the working area. | ||
7 | Remove bracket (1). | For this purpose, remove nuts. | |
8 | Install in the reverse order. |
Powiązane dokumenty
- ah0000z030001a Ogólne wskazówki dotyczące pojazdów z instalacją wysokiego napięcia i/lub akumulatorem litowo-jonowym i/lub gazowym systemem napędu oraz osobistego wyposażenia ochronnego
- ah0060n010001a Wskazówki dotyczące podnoszenia pojazdu, ustawiania na podporach
- ar0850s0016f
- ar0850s0120f
- ar6000s0023e
- ar6210s0001e
- ar8810s1300e
- as0000z001001a Zagrożenie życia na skutek ześlizgnięcia lub spadnięcia pojazdu z podnośnika.
- as0000z003501a Zagrożenie życia podczas prac przy elementach i systemach U >=30 V napięcie zmienne (AC) bądź U >=60 V napięcie zmienne