Shown on model 257 except code B01 (48V technology) |
1 | Ground cable |
2 | Electrical connector |
3 | Nut |
B95 | Battery sensor |
G1 | On-board electrical system battery |
P54.10-3989-12
Danger | Risk of fire/risk of explosion due to short circuit and escaping oxyhydrogen gas. Risk of (burn) injury caused by caustic burns to eyes, skin and mucous membranes from battery electrolyte/mist, short circuit and arcing. Risk of poisoning caused by swallowing battery electrolyte or absorption of lead through the skin or body orifices. Risk of death due to voltage U >= 30 V AC and U >= 60 V DC. | No fires, sparks, open flames, or smoking. Wear acid-resistant gloves, clothing, and glasses. Pour battery acid only into suitable and appropriately marked containers. | |
Topical note | Notes on battery | ||
| Remove/install | ||
1 | Disconnect ground line (1) from on-board electrical system battery (G1). | ||
2 | Release and disconnect electrical connector (2). | ||
3 | Unscrew nut (3) and remove ground line (1) with battery sensor (B95). | The ground line (1) and the battery sensor (B95) are one component and cannot be replaced individually. | |
Rear on-board electrical system battery ground point | |||
Left on-board electrical system battery ground point | |||
Right on-board electrical system battery ground point | |||
4 | Install in the reverse order. |
Powiązane dokumenty
- ah5410p000101a Wskazówki dotyczące akumulatora
- ah5410p000101a
- ar5410p0003fr