AR47.70-S-1020-01G | Check ground lines for high-voltage on-board electrical system potential equalization | ||
Danger | Risk of death when working on component parts and systems with U >= 30 V alternating voltage (AC) or U >= 60 V direct voltage (DC) | Do not touch damaged or defective live component parts and lines or non-insulated electrical connections and lines. | |
Topical note | Notes on battery | ||
Topical note | General information on vehicles with high-voltage on-board electrical system and/or lithium-ion battery and/or gaseous-fuel drive system as well as personal protective equipment | ||
Topical note | Information on preventing damage to electronic components due to electrostatic discharge |
When performing work on the high voltage components, the ground lines for the potential equalization must be checked.
Check potential equalization of side axle drive module to assembly carrier
1 | Check potential equalization ground line (1) for damage. |
If damage is present, | |
| |
Replace potential equalization ground line (1) . |
2 | Check that potential equalization ground line (1) is firmly seated. |
If potential equalization ground line (1) is loose: | |
| |
Secure potential equalization ground line (1) . |
S47.70-A055-74
Check potential equalization of lower axle drive module to high-voltage battery
3 | Check potential equalization ground line (2) at axle drive module for damage. |
If damage is present, | |
| |
Replace potential equalization ground line (2) . |
4 | Check that the potential equalization ground line (2) is seated tightly. |
If the potential equalization ground line (2) is loose: | |
| |
secure the potential equalization ground line (2) . |
S47.70-A056-75
Check potential equalization of high-voltage battery to body
5 | Check the potential equalization ground line (3) for damage. |
If damage is present, | |
| |
Replace potential equalization ground line (3) . |
6 | Check that potential equalization ground line (3) is firmly seated. |
If the potential equalization ground line (3) is loose: | |
| |
secure the potential equalization ground line (3) . |
S47.70-A057-74
Check potential equalization of auxiliary circuit heater to subharness
7 | Check the potential equalization ground line (4) for damage. |
If damage is present: | |
| |
Perform appropriate repair measures to repair potential equalization ground line (4) . |
8 | Check that the potential equalization ground line (4) is seated tightly. |
If the potential equalization ground line (4) is loose: | |
| |
secure the potential equalization ground line (4) . |
S47.70-A058-74
Check potential equalization of vehicle interior heater to subharness
9 | Check the potential equalization ground line (5) for damage. |
If damage is present, | |
| |
Perform appropriate repair measures to repair potential equalization ground line (5) . |
10 | Check that the potential equalization ground line (5) is seated tightly. |
If the potential equalization ground line (5) is loose: | |
| |
secure the potential equalization ground line (5) . |
S47.70-A059-74
Check feed-in socket protective ground conductor to DC current charge-connection unit
11 | Check electric line (6) for damage. |
If damage is present: | |
| |
Perform appropriate repair measures to repair electric line (6) . |
12 | Check that electric line (6) is firmly seated. |
If electric line (6) is loose: | |
| |
Secure electric line (6) . |
S47.70-A060-81
Check potential equalization of AC charger to subharness
13 | Check the potential equalization ground line (7) for damage. |
If damage is present: | |
| |
Perform appropriate repair measures to repair potential equalization ground line (7) . |
14 | Check that the potential equalization ground line (7) is seated tightly. |
If the potential equalization ground line (7) is loose: | |
| |
secure the potential equalization ground line (7) . |
S47.70-A061-74
Check potential equalization of DC/DC converter to subharness
15 | Check potential equalization ground line (8) for damage. |
If damage is present: | |
| |
Perform appropriate repair measures to repair potential equalization ground line (8) . |
16 | Check that potential equalization ground line (8) is firmly seated. |
If potential equalization ground line (8) is loose: | |
| |
Secure potential equalization ground line (8) . |
S47.70-A062-74
Check potential equalization of high-voltage power distributor in engine compartment to assembly carrier
17 | Check the potential equalization ground line (9) for damage. |
If damage is present, | |
| |
Replace potential equalization ground line (9) . |
18 | Check that the potential equalization ground line (9) is seated tightly. |
If the potential equalization ground line (9) is loose: | |
| |
secure the potential equalization ground line (9) . |
S47.70-A063-74
Check potential equalization of DC current charge-connection unit to assembly carrier
19 | Check the potential equalization ground line (10) for damage. |
If damage is present, | |
| |
Replace potential equalization ground line (10) . |
20 | Check that the potential equalization ground line (10) is seated tightly. |
If the potential equalization ground line (10) is loose: | |
| |
secure the potential equalization ground line (10) . |
S47.70-A064-74
Check potential equalization of subharness to body
21 | Check the potential equalization ground line (11) for damage. |
If damage is present: | |
| |
Perform appropriate repair measures to repair potential equalization ground line (11) . |
22 | Check that the potential equalization ground line (11) is seated tightly. |
If the potential equalization ground line (11) is loose: | |
| |
secure the potential equalization ground line (11) . |
S47.70-A065-04
Powiązane dokumenty
- ah0000z030001a Ogólne wskazówki dotyczące pojazdów z instalacją wysokiego napięcia i/lub akumulatorem litowo-jonowym i/lub gazowym systemem napędu oraz osobistego wyposażenia ochronnego
- ah5400p000101a Wskazówki dotyczące zapobiegania uszkodzeniom elementów elektronicznych na skutek rozładowania potencjału elektrostatycznego
- ah5410p000101a Wskazówki dotyczące akumulatora
- ah5410p000101a
- as0000z003501a Zagrożenie życia podczas prac przy elementach i systemach U >=30 V napięcie zmienne (AC) bądź U >=60 V napięcie zmienne