AR47.25-D-4100-01TS | Disconnect, connect connector coupling with double lock on fuel line | ||
Danger | Risk of explosion caused by fuel igniting, risk of poisoning caused by inhaling and swallowing fuel as well as risk of injury to eyes and skin caused by contactwith fuel. | No fires, sparks, open flames or smoking. Pour fuels into suitable and appropriately marked containers only. |
D47.25-1135-09
Disconnect connector coupling (4)
1 | Insert suitable screwdriver into cutout (1). |
2 | Release lock clamp (2) from coupling socket (3). |
To do this, pull lock clamp (2) upward with the screwdriver up to the release position (arrow A). |
3 | Disconnect connector coupling (4) from fuel line (5). |
To do this, pull coupling plug (6) from coupling socket (3). |
Connect connector coupling (4)
4 | Prepare lock clamp (2) on coupling socket (3) for installation. |
When reusing the old coupling socket (3). |
To do this, press in the lock clamp (2) up to the connection position (arrow B). |
The coupling socket (3) is located in the connection position (arrow B) in the ready for installation delivery condition. |
5 | Connect connector coupling (4) with fuel line (5). |
To do this, insert the coupling plug (6) into the coupling socket (3) until the connector coupling (4) clearly locks audibly. Then, check that it is connected correctly by pulling it back slightly. |
If the coupling plug (6) can be pulled out of the coupling socket (3), |
Insert coupling plug (6) into the coupling socket (3) again.
6 | Lock connector coupling (4). |
To to this, press in lock clamp (2) on coupling socket (3) up to the lock position (arrow C). |