ar4725d410001ts

Disconnect, connect connector coupling with double lock on fuel line

Typ ar · temat 47.25 · wersja 0100 · 2018-06-04

Dotyczy: Model 907, 910

Niedostępne w języku „pl”; wyświetlono w języku Angielski.

Umiejscowienie

Grupa funkcyjna 1 Silnik › 47 Układ paliwowy, zasilanie energią zespołu napędowego › 47.25 Przewody, przewody elastyczne — Seria 907 · Seria 910

EinPAS 16 Zasilanie paliwem/ energią silnika › 16.10 Zasilanie paliwem › 16.10.13 Przewód sztywny/elastyczny/zawór — Seria 907 · Seria 910

AR47.25-D-4100-01TS

Disconnect, connect connector coupling with double lock on fuel line

Danger

Risk of explosion caused by fuel igniting, risk of poisoning caused by inhaling and swallowing fuel as well as risk of injury to eyes and skin caused by contactwith fuel.

No fires, sparks, open flames or smoking. Pour fuels into suitable and appropriately marked containers only.
Wear protective clothing when handling fuel.

AS47.00-Z-0001-01A

Model

907, 910

Disconnect, connect connector coupling with double lock on fuel line

D47.25-1135-09

Disconnect connector coupling (4)

1

Insert suitable screwdriver into cutout (1).

2

Release lock clamp (2) from coupling socket (3).

To do this, pull lock clamp (2) upward with the screwdriver up to the release position (arrow A).

3

Disconnect connector coupling (4) from fuel line (5).

To do this, pull coupling plug (6) from coupling socket (3).

Connect connector coupling (4)

4

Prepare lock clamp (2) on coupling socket (3) for installation.

When reusing the old coupling socket (3).

To do this, press in the lock clamp (2) up to the connection position (arrow B).

The coupling socket (3) is located in the connection position (arrow B) in the ready for installation delivery condition.

5

Connect connector coupling (4) with fuel line (5).

To do this, insert the coupling plug (6) into the coupling socket (3) until the connector coupling (4) clearly locks audibly. Then, check that it is connected correctly by pulling it back slightly.

If the coupling plug (6) can be pulled out of the coupling socket (3),

Insert coupling plug (6) into the coupling socket (3) again.

6

Lock connector coupling (4).

To to this, press in lock clamp (2) on coupling socket (3) up to the lock position (arrow C).