AR20.10-P-1272SM | Remove, install circulation pump | 23.3.05 |
ENGINE 160.910, 660.940 in MODEL 450.3 /4 up to 10.2.02
P20.10-2189-09
1 Circulation pump power supply
2 Coolant hose hose clamps
5 Circulation pump
3 Coolant hoses
4 Bolt for retaining clamp
| Remove/Install | ||
Danger! | Risk of explosion caused by fuel igniting, risk of poisoning caused by inhaling and swallowing fuel as well as risk of injury to eyes and skin caused by contact with fuel. | No fire, sparks, open flames or smoking. Wear protective clothing when handling fuel. | |
Danger! | Risk of injury to skin and eyes from handling hot or glowing objects. | Wear safety gloves, protective clothing and safety glasses, if necessary. | |
Danger! | Risk of injury to skin and eyes caused by scalding from contact with hot coolant spray. Risk of poisoning from swallowing coolant. | Do not open cooling system unless coolant temperature is below 90 °C. Open cap slowly and release the pressure. Do not pour coolant into beverage bottles. Wear protective gloves, protective clothing and eye protection. | |
1 | Perform short test with diagnosis equipment | ||
| Connect STAR DIAGNOSIS and read out fault memory | ||
STAR DIAGNOSIS diagnosis system | |||
2 | Disconnect battery ground cable | ||
3 | Drain coolant | ||
4 | Remove underfloor paneling | ||
5 | Disconnect circulation pump power supply (1) | ||
6 | Loosen the coolant hose hose clamps (2) | ||
7 | Pull coolant hoses (3) off the circulation pump (5) | ||
8 | Unscrew bolt of retaining clamp (4) at circulation pump (5) | ||
9 | Remove circulation pump (5) | Installation: Pay attention to the installation position of the circulation pump rubber. | |
10 | Install in the reverse order | ||
11 | Perform a function test |
Commercially available tools
Powiązane dokumenty
- ad0000p200004sm
- ar2000p1142sm
- ar2000p1142smg Spuść, napełnij układ płynem chłodzącym.
- ar5410p0003sm
- ar6130p1001sm
- ar8370p2028sm
- as0000z000201a Niebezpieczeństwo zranienia skóry i oczy na skutek kontaktu z gorącymi lub żarzącymi się przedmiotami
- as2000z000101a Niebezpieczeństwo zranienia skóry i oczu przez poparzenie wytryskującym, gorącympłynem chłodzącym. Niebezpieczeństwo zatrucia na skutek połknięcia płynu chłodzącego
- as4700z000101a Niebezpieczeństwo wybuchu wskutek zapalenia, niebezpieczeństwo zatrucia wskutek wdychania i połknięcia paliwa oraz niebezpieczeństwo obrażeń wskutek kontaktu skóry i oczu z paliwem.