2 | Lock lever |
3 | Electrical connections |
4 | Nuts |
5 | Screw/bolts |
6 | Retaining frame |
N3/21 | CDI control unit |
D07.08-1120-06
Danger ! | Risk of explosion from explosive gas. Risk of poisoning and caustic burns from swallowing battery electrolyte. Risk of injury through burns to skin and eyes from battery acid or when handling damaged lead-acid batteries | No fires, sparks, open flames or smoking. Wear acid-resistant gloves, clothing and glasses. Only pour battery acid into suitable and appropriately marked containers. | |
| Information on preventing damage to electronic components due to electrostatic discharge | ||
| Remove/install | ||
1 | Read out variant coding for CDI control unit (N3/21) | When replacing CDI control unit (N3/21) | |
| |||
2 | Remove battery | ||
| Notes on battery | ||
3 | Remove battery carrier | ||
4 | Unfasten lock lever (2) and disconnect electrical connection (3) on CDI control unit (N3/21) | Installation: Ensure correct seating of seals in the electrical connections (3). | |
5 | Unscrew nuts (4) | ||
6 | Remove CDI control unit (N3/21) and retaining frame (6) | ||
7 | Remove screw/bolts (5) | ||
8 | Remove CDI control unit (N3/21) to the front (arrow) from retaining frame (6) | ||
9 | Install in the reverse order | ||
10 | Connect diagnostic system, read out fault memory and delete if necessary | ||
|
Powiązane dokumenty
- ad0000d200004f
- ah5400p000101a Wskazówki dotyczące zapobiegania uszkodzeniom elementów elektronicznych na skutek rozładowania potencjału elektrostatycznego
- ah5410p000101a Wskazówki dotyczące akumulatora
- ah5410p000101a
- as5410z000101a Niebezpieczeństwo pożaru/wybuchu z powodu zwarcia i wydostającego się gazu piorunującego. Niebezpieczeństwo obrażeń z powodu poparzenia oczu, skóry i śluzówki przez elektrolit akumulatora/mgiełkę lub przez zwarcie i działanie