1 | Hot film mass air flow sensor |
2 | Seal |
3 | Clean air line |
4 | Housing |
S07.07-A003-75
| Remove | ||
1 | Remove clean air line (3). | ||
2 | Remove respective hot film mass air flow sensor (1). | The hot film mass air flow sensors (1) each form a single unit with their housings (4). | |
To do this, pry the corresponding housing (4) out of the clean air line (3). | |||
Long wedge | |||
| Check | ||
3 | Check seal (2) between the housing (4) and clean air line (3) for damage. | If seal (2) is damaged, | |
| |||
replace clean air line (3). | |||
4 | Check sealing surface of the housing (4) for damage. | If the sealing surface of the housing (4) is damaged, | |
| |||
replace housing (4) with hot film mass air flow sensor (1). | |||
| Install | ||
5 | Install respective hot film mass air flow sensor (1) with housing (4). | | |
If the sealing surface of the housing (4) is not seated correctly, | |||
| |||
correct positioning of the housing (4) in the clean air line (3). | |||
6 | Install new clean air line (3). |
115 589 03 59 00
Long wedge