P05.20-2424-09
Shown on engine 281.910 |
1 | Electrical connection | 3 | Timing case cover | Y49/10 | Variable camshaft adjustment valve | ||
2 | Screw/bolt | 4 | Sealing ring |
| Remove/install | ||
1 | Remove covering over engine | Installation: Only install covering over engine after a leak test. | |
2 | Disconnect electrical connection (1) on variable camshaft adjustment valve (Y49/10) | ||
3 | Remove screw/bolt (2) | Bolt, valve for variable camshaft adjustment to timing case cover | |
4 | Remove variable camshaft adjustment valve (Y49/10) from the timing case cover (3) | Installation: Replace sealing ring (4). | |
5 | Install in the reverse order | ||
6 | Connect diagnostic unit and read out fault memory | For replacing the variable camshaft adjustment valve (Y49/10). | |
| |||
| Check | ||
Danger ! | Risk of accident from vehicle starting off by itself when engine running. Risk of injury (bruises and burns) resulting from working on the engine while it is being started or when it is running. | Secure vehicle to prevent it from starting off by itself. Wear closed and snug-fitting work clothes. Do not touch hot or rotating parts. | |
7 | Perform engine test run and check engine for leaktightness in area of variable camshaft adjustment valve (Y49/10) |