1 | Cover |
2 | Cooktop grates |
3 | Flame panels |
4 | Bolts |
5 | Valves |
6 | Warning |
N00.10-2553-06
Danger ! | Risk of explosion due to escaping combustible gas or overheating of gas cylinders.Risk of injury caused by burns to skin and eyes. Risk of frostbite to body parts caused by escaping gas and by touching components near the valves when emptying gas cylinders. Risk of poisoning or suffocation caused by inhaling gas. | Remove any sources of ignition. | |
| Check | ||
1 | Open cover (1) | ||
2 | Check whether the warning note (6) is present | ||
3 | Check cooktop grates (2) for damage | If they are damaged, the cooktop grates (2) must be replaced. | |
4 | Check flame panels (3) for signs of damage | If they are damaged, the flame panels (3) must be replaced. | |
5 | Check screws/bolts (4) are firmly seated, retighten if necessary | ||
6 | Activate cooker | Check flame for good burn-off. | |
If burn-off is faulty | |||
| |||
Clean or replace gas outlet, if necessary | |||
Remove/install gas outlet from stove | |||
7 | Deactivate cooker | ||
8 | Check ignition locking mechanism for proper function | To do so, open valves (5), after approx. 60 s an audible switch-off must be heard. |