1 | Charging cable |
2 | Vehicle socket |
3 | Cap |
4 | Sequence |
G54.10-3294-75
Danger | Risk of death when working on component parts and systems with U >= 30 V alternating voltage (AC) or U >= 60 V direct voltage (DC) | Do not touch damaged or defective live component parts and lines or non-insulated electrical connections and lines. | |
Topical note | General information on vehicles with high-voltage on-board electrical system and/or lithium-ion battery and/or gaseous-fuel drive system as well as personal protective equipment | ||
Topical note | Information on preventing damage to electronic components due to electrostatic discharge | ||
Topical note | Notes on battery | ||
| Check | ||
1 | Check entire length of charging cable (1), plugs and switches for cracks, kinks, bites, cuts, crushed areas, chafe marks and other damage. | If problems occur, | |
| |||
replace charging cable (1). | |||
After obtaining special order. | |||
2 | Check vehicle socket (2) for damage. | If problems occur, | |
| |||
Replace vehicle socket (2). | |||
After obtaining special order. | |||
3 | Check cap (3) is firmly seated on vehicle socket (2). | If problems occur, | |
| |||
Replace vehicle socket (2). | |||
After obtaining special order. | |||
4 | Check drain (4) for clear passage and soiling. | | |
If problems occur, | |||
| |||
rectify the problems. | |||
After obtaining special order. |