ar8370d117802b
Evaluating delivery quantity of fuel metering pump
Type ar · thema 83.70 · versie 0100 · 1997-02-07
Geldig voor: MODEL 901.06, 902.06 /07, 903.06 /07, 904.06 with CODE (H11) Hot air auxiliary heater Heater designation B3L-C MODEL 901.36 /37 /46, 902.36 /37 /46 /47, 903.36 /37 /46 /47, 904.36 /46 with CODE (H11) Hot air auxiliary heater Heater designation D3L-C
Niet beschikbaar in “nl”; getoond in Engels.
Plaats
Functiegroep 3 Opbouw/carrosserie › 83 Temperatuurregeling › 83.70 Standverwarming, extra verwarming — Serie 901 (modellen 06*, 36*, 37*, 46*) · Serie 902 (modellen 06*, 07*, 36*, 37*, 46*, 47*) · Serie 903 (modellen 06*, 07*, 36*, 37*, 46*, 47*) · Serie 904 (modellen 06*, 36*, 46*)
EinPAS 39 Verwarming/ventilatie/koeling › 39.25 Interieurvoorverwarming/standverwarming/extra verwarming › 39.25.46 Pomp/reservoir — Serie 901 (modellen 06*, 36*, 37*, 46*) · Serie 902 (modellen 06*, 07*, 36*, 37*, 46*, 47*) · Serie 903 (modellen 06*, 07*, 36*, 37*, 46*, 47*) · Serie 904 (modellen 06*, 36*, 46*)
AR83.70-D-1178-02B
| Evaluating delivery quantity of fuel metering pump
|
|
|
1 Enter voltage reading (V) on vertical axis in appropriate diagram.
2 Enter the quantity of fuel delivered in 90 sec. (in ml) on the horizontal axis in the appropriate diagram.
3 Determine intersection point of the two readings.
If the intersection point is within the two limits in the appropriate diagram, the fuel metering pump is okay.
Auxiliary heater D3L-C (diesel)
Auxiliary heater B3L-C (gasoline)