ar8370d117802b

Evaluating delivery quantity of fuel metering pump

Type ar · topic 83.70 · version 0100 · 1997-02-07

Applies to: MODEL 901.06, 902.06 /07, 903.06 /07, 904.06 with CODE (H11) Hot air auxiliary heater Heater designation B3L-C MODEL 901.36 /37 /46, 902.36 /37 /46 /47, 903.36 /37 /46 /47, 904.36 /46 with CODE (H11) Hot air auxiliary heater Heater designation D3L-C

Where it sits

Function group 3 Body › 83 Climate control › 83.70 Auxiliary/supplementary heater — Series 901 (models 06*, 36*, 37*, 46*) · Series 902 (models 06*, 07*, 36*, 37*, 46*, 47*) · Series 903 (models 06*, 07*, 36*, 37*, 46*, 47*) · Series 904 (models 06*, 36*, 46*)

EinPAS 39 Heating/ventilation/cooling › 39.25 Stationary heater/auxiliary heater › 39.25.46 Pump/container — Series 901 (models 06*, 36*, 37*, 46*) · Series 902 (models 06*, 07*, 36*, 37*, 46*, 47*) · Series 903 (models 06*, 07*, 36*, 37*, 46*, 47*) · Series 904 (models 06*, 36*, 46*)

AR83.70-D-1178-02B

Evaluating delivery quantity of fuel metering pump

1 Enter voltage reading (V) on vertical axis in appropriate diagram.

2 Enter the quantity of fuel delivered in 90 sec. (in ml) on the horizontal axis in the appropriate diagram.

3 Determine intersection point of the two readings.

If the intersection point is within the two limits in the appropriate diagram, the fuel metering pump is okay.

Evaluating delivery quantity of fuel metering pump
Evaluating delivery quantity of fuel metering pump

D83.70-0027-01

Auxiliary heater D3L-C (diesel)

Auxiliary heater B3L-C (gasoline)

D83.70-0028-01