ar5430d0001a

Remove/install tachograph

Type ar · thema 54.30 · versie 0105 · 2006-07-26

Geldig voor: MODEL 901.6, 902.6, 903.6, 904.6, 905.6 with CODE (J19) 1 day/2 driver automatic tachograph (EC) MODEL 901.6, 902.6, 903.6, 904.6, 905.6 with CODE (J28) tachograph, 1 day / 2 drivers with additional recorder MODEL 690.6 with CODE (J05) Tachograph for Latin America

Niet beschikbaar in “nl”; getoond in Engels.

Plaats

Functiegroep 2 Onderstel › 54 Elektrisch installatie, uitrusting en instrumenten › 54.30 Combi-instrument, indicatie-instrumenten — Serie 690 (modellen 6**) · Serie 901 (modellen 6**) · Serie 902 (modellen 6**) · Serie 903 (modellen 6**) · Serie 904 (modellen 6**) · Serie 905 (modellen 6**)

EinPAS 31 Communicatie/informatie/entertainment › 31.35 Tachograaf/tolsysteem › 31.35.40 Tachograaf — Serie 690 (modellen 6**) · Serie 901 (modellen 6**) · Serie 902 (modellen 6**) · Serie 903 (modellen 6**) · Serie 904 (modellen 6**) · Serie 905 (modellen 6**)

AR54.30-D-0001A

Remove/install tachograph

1.9.99

MODEL 901.6, 902.6, 903.6, 904.6, 905.6 with CODE (J19) 1 day/2 driver automatic tachograph (EC)

MODEL 901.6, 902.6, 903.6, 904.6, 905.6 with CODE (J28) tachograph, 1 day / 2 drivers with additional recorder

MODEL 690.6 with CODE (J05) Tachograph for Latin America

Remove/install tachograph
Remove/install tachograph

D54.61-1105-01

1 Tachograph

2 Removal tool

3 Anti-tamper seal

4 Cover

D54.61-1102-01

Remove/Install

1

Insert removal tools (2) into tachograph (1) next to drawer on left and right and push all the way in. Press removal tools down a little and pull out tachograph using removal tools.

Installation: Insert tachograph until it latches audibly.

*WH58.30-Z-1007-19A

2

Remove anti-tamper seal (3).

Installation: Replace anti-tamper
lead seal.

*102589033300

3

Remove cover (4)

Push the cover up to release the detent mechanism, then remove by extracting to the rear.

4

Disconnect electrical connections

Removal: Identify plug.

Installation: Only plug connections
"A" and "B" are assigned.

5

Install in the reverse order

Following installation of the new tachograph, the operational parameters must be programmed into the unit using the Kienzle diagnosis unit.

Remove/install tachograph

Extractor

102 589 03 33 00

Commercially available tools

Number

Designation

WH58.30-Z-1007-19A

Tachograph removal tool (MTCO)

000 545 0744