SM42.20-L-0007B | Check compressed air system | 18.2.99 |
MODELS 668.###, 670.### ## as of 070981 up to 30.11.98
except CODE (B16) 2-circuit hydraulic brake/2-circuit compressed air brake
except CODE (B19) Hydraulic 2-circuit / compressed air 2-circuit heavy-duty brakes
N42.20-2028-01
Figure 1
V1 Boiler
P1 Test connector
B13 Switch, red
B14 Switch, yellow
B74 Switch, blue
B75 Switch, without
identification
Fig. 2
N42.20-2022-01
N42.20-2033-01
Fig. 3
P2 Test connector
1 Adjustment screw
2 Overflow valve
V2 Boiler
B12 Switch
Fig. 4
N42.20-2034-01
N42.20-2035-01
Figure 5
P3 Test connector
Figure 6
N42.20-2026-01
Operation no. of operation texts or standard texts and flat rates
Range | Op. no. | Operation text |
N | 023721 | CHECKING OPERATION AND TIGHTNESS OF COMPRESSED AIR SYSTEM |
| Testing | ||
1 | Check readiness lamp (brake lining wear indicator "!") (figures 1 and 2) | Measure pressure at test connection P1 Switch on using switch B13 when pressure drops below 5.5 bar 0.3 bar. Switch off using switch B14 when pressure rises above 8.4 bar 0.4 bar | |
2 | Supply pressure lamp ("Boiler" lamp, right side of instrument cluster) at boiler V2 (figures 3 and 4) | Measure pressure at test connection P2 Switch B12, on/off switching point 5.8 bar 0.3 bar | |
3 | Depressurize system | ||
5 | Attach 2 pressure gauges to test connections P1 and P2 | ||
6 | Measure overflow valve setting | Measure pressure at which overflow valve opens and fills boiler V2. Specified value 9.6 bar - 0.3 bar | |
7.1 | Make overflow valve setting by adjusting screw | Only if there is a difference | |
8 | Check parking lamp "P" (figure 5) | Measure with handbrake off, test connection P3. Switch B5, on/off switching point 5.8 bar 0.3 bar | |
9 | Check compressor on/off switching points | Read off pressure at test connection P1 Switch B75, compressor switch-on point 10.5 bar 0.5 bar Switch B74, compressor switch-off point 12.0 bar 0.5 bar | |
10 | Check compressed air dryer drain valve | After the ignition is switched on and the compressor switched off, the drain valve opens for approx. 4 sec. (audible hissing noise). |