gf8320d4010h

Coolant circulation pump component description

유형 gf · 주제 83.20 · 버전 0101 · 2009-05-15

적용 대상: MODEL 906 with CODE (HH9) "Tempmatic" regulated air conditioning MODEL 906 with CODE (H12) Auxiliary heater (warm water) MODEL 906 with CODE (HZ9) Heater booster, diesel MODEL 906 with CODE (HZ5) 10 kW warm water auxiliary heater with timer MODEL 906 with CODE (H13) Additional heat exchanger in cargo area

“ko”(으)로는 제공되지 않아 영어(으)로 표시합니다.

위치

기능 그룹 3 구조 › 83 에어컨 › 83.20 히터 — 시리즈 906

GF83.20-D-4010H

Coolant circulation pump component description

22.4.09

MODEL 906 with CODE (HH9) "Tempmatic" regulated air conditioning

MODEL 906 with CODE (H12) Auxiliary heater (warm water)

MODEL 906 with CODE (HZ9) Heater booster, diesel

MODEL 906 with CODE (HZ5) 10 kW warm water auxiliary heater with timer

MODEL 906 with CODE (H13) Additional heat exchanger in cargo area

On vehicles with code (HH9) Regulated air conditioning (Tempmatic), the circulation pump (M13/4) for the engine residual heat utilization function is installed up to August 31, 2008. As of September 1, 2008, the circulation pump is only available if one of the following special equipment packages is also installed:

- Code (HZ5) 10 kW auxiliary water heater with timer

- Code (HZ9) Heater booster, diesel

- Code (H12) Auxiliary heater (warm water)

- Code (H13) Additional heat exchanger in cargo area

Coolant circulation pump component description

D83.20-1115-12

Location

M13/4 Circulation pump

The circulation pump is located in the engine compartment between the firewall and the engine below the air filter box.

Task

The circulation pump alone assures circulation in the coolant circuit when the engine is off; when the engine is running, it is supported by the water pump.

The circulation pump is actuated via the following components:

- KLA control and operating unit (S98), with code (HH9) Regulated air conditioning (Tempmatic)

- Warm water auxiliary heater control unit (N33/3), with code (H12) Auxiliary heater (warm water) or with code (HZ5) 10 kW auxiliary water heater with timer and except code (HH9) Regulated air conditioning (Tempmatic)

- 2nd warm water auxiliary heater control unit (N33/2), with code (HZ9) Heater booster, diesel or with code (HZ5)
10 kW auxiliary water heater with timer and except code (HH9) Regulated air conditioning (Tempmatic)