기능 그룹 3 구조 › 77 선루프, 폴딩루프, 탑 › 77.20 선루프 전기장치 — 시리즈 202 · 시리즈 208 (모델 3**) · 시리즈 210 (모델 003, 004, 006, 007, 010, 015, 016, 017, 020, 025, 026, 035, 037, 045, 048, 053, 055, 061, 062, 063, 065, 070, 072, 074, 081, 082, 083, 206, 210, 215, 216, 217, 225, 226, 235, 237, 245, 248, 261, 262, 263, 265, 270, 272, 274, 281, 282, 283, 606, 610, 616, 617, 663)

GF77.20-P-2002A

Close tilting/sliding roof function

23.1.97

MODELS 202 as of 1.6.97,
208, 210.081 /281 (except 208.4),
210 (except 210.081 /281) as of 1.3.97

Function prerequisites

no overvoltage/undervoltage

Function

The close tilting/sliding roof function is only available in the normalized state of the tilting/sliding roof. It is triggered by pulling the tilting/sliding roof switch (N70s1) downward.

The overhead control panel control module (N70) then actuates the

-----------------------------------------------------------------------------------------

motor of the tilting/sliding roof (M12/1). The direction in which the motor is actuated depends on whether the sliding roof or the tilting roof is open. The motor is actuated until the overhead control panel control module (N70) through the position measurement detects that the tilting/sliding roof is closed, or lock-up of the tilting/sliding roof is detected.

-----------------------------------------------------------------------------------------

Opening pop-up roof, function

GF77.20-P-2003A

Open sliding roof function

GF77.20-P-2004A

Sliding/pop-up roof lock-up recognition, function

GF77.20-P-3000A

Tilting/sliding roof (SR) position measurement, function

GF77.20-P-3001A

Tilting/sliding roof (SR) normalization, function

GF77.20-P-3002A

Tilting/sliding roof motor

GF77.20-P-4100A

Overhead control panel control module

GF82.20-P-4101A

참조 문서