ar9710d4000a

Seam sealing following repair

유형 ar · 주제 97.10 · 버전 0109 · 2003-09-17

적용 대상: MODEL 901, 902, 903, 904, 905 MODELS WD1, WD2, WD3, WD6, WD7, XD1, XD2, XD3, XD4, XD5, XD6, XD7, YD1, YD2, YD3, YD4, YD5, YD6, YD7 MODELS 690.6

“ko”(으)로는 제공되지 않아 영어(으)로 표시합니다.

위치

기능 그룹 3 구조 › 97 바디실링, 언더바디코팅 › 97.10 바디실링 — 시리즈 690 (모델 6**) · 시리즈 901 · 시리즈 902 · 시리즈 903 · 시리즈 904 · 시리즈 905

EinPAS 40 방청 처리/도장 › 40.20 부식 방지 › 40.20.30 심 실링 — 시리즈 690 (모델 6**) · 시리즈 901 · 시리즈 902 · 시리즈 903 · 시리즈 904 · 시리즈 905

AR97.10-D-4000A

Seam sealing following repair

2.7.96

MODEL 901, 902, 903, 904, 905

MODELS WD1, WD2, WD3, WD6, WD7, XD1, XD2, XD3, XD4, XD5, XD6, XD7, YD1, YD2, YD3, YD4, YD5, YD6, YD7

MODELS 690.6

Seam sealing following repair

N98.00-0631-09

Illustration: 1 vehicle with left-hand steering

Illustration: 2 vehicle with right-hand steering

D Concealed fine seam sealing

A Fine seam sealing

C Airless sealing

Seam sealing following repair

N98.00-0632-09

A Fine seam sealing

B Outer body seam sealing on top coat

D Concealed fine seam sealing

C Airless sealing

Seam sealing following repair

N98.00-0633-09

A Fine seam sealing

1 Drain holes in entry

Fig. item, etc.

Work instructions

Danger!

Risk of explosion and poisoning.. Solvent vapors and fumes are explosive and toxic. Risk of injury. Working with anticorrosion agents may result in eye and skin injuries.

Never spray anticorrosion agents on flames or glowing hot objects and keep them well away from all potential sources of ignition. Process in well-ventilated rooms, wear respiratory protection.

AS97.00-Z-0001-01A

Notes on sprayable joint sealant

MODEL all

AH97.10-P-0002-01A

Sealing

After performing body repair seal welds on both sides.

AR97.20-P-0500A

Sealant

Processing instructions

AR97.10-P-0500-02A

Corrosion protection

Do not apply sealing agent on bare metal, prime welds, etc. first

Detachable body components

When replacing detachable body components such as doors, engine hood, rear doors etc. also seam welds and beads.

Separation points

In some cases various sealing measures may be required at points not illustrated depending on the scope of repair.

1

Drain holes in entry

Keep drain holes in entry free.