AR83.70-P-5302GL | Remove/install heater unit | 12.9.02 |
MODEL 461.302 /331 /332 /342 /345 with ENGINE 612.966 with CODE (H12) Auxiliary heater
MODEL 463.322 /323 with ENGINE 612.965 with CODE (H12) Auxiliary heater
P83.70-4229-06
1 Coolant outlet hose
2 Coolant feed hose
3 Fuel pipe
4 Electrical connector
5 Electrical connector
6 Tie strap
7 Exhaust line
8 Securing bolts
A6 STH or HB heater unit
| Remove/Install | ||
Danger! | Risk of injury to skin and eyes suffering scalding from contact with hot coolant spray. Risk of poisoning from swallowing coolant. | Do not open cooling system unless coolant temperature is below 90 °C. Open cap slowly and release the pressure. Do not pour coolant into beverage bottles. Wear protective gloves, protective clothing and eye protection. | |
Danger! | Risk of death cased by vehicle slipping or toppling off of the lifting platform. | Align vehicle between the columns of the hydraulic hoist and position the four support plates below the hoist support points specified by the vehicle manufacturer. | |
1 | Lift/jack up vehicle | ||
2 | Remove underride guard | ||
3 | Drain coolant | ||
| |||
| Notes on coolant | All engines | |
4 | Disconnect coolant feed hose (2) and coolant outlet hose (1) to STH or HB heater unit (A6) and coolant pump | Catch coolant with suitable vessel. | |
Danger! | Risk of explosion caused by fuel vapors igniting, risk of poisoning caused by inhaling combustible gases and risk of injury caused by burns during and after operation of heater unit | Do not operate stationary heater, auxiliary heater or engine with heater booster in closed areas or when refueling. Allow heater unit to cool down after operation and wear protective gloves. | |
5 | Disconnect fuel line (3) from the STH or HB heater unit (A6) | Catch fuel running out with suitable vessel. | |
6 | Disconnect electrical connectors (4, 5) from electrical connection lines. | Installation: replace tie straps (6). | |
7 | Disconnect exhaust line (7) from STH or HB heater unit (A6) | ||
8 | Disconnect air supply line from STH or HB heater unit (A6) | ||
9 | Remove STH or HB heater unit (A6) | Loosen mounting screws (8) and lift out STH or HB heater unit (A6). | |
10 | Remove coolant circulation pump | ||
11 | Install in the reverse order | ||
12 | Pour in coolant | ||
| |||
Danger! | Risk of explosion caused by fuel vapors igniting, risk of poisoning caused by inhaling combustible gases and risk of injury caused by burns during and after operation of heater unit | Do not operate stationary heater, auxiliary heater or engine with heater booster in closed areas or when refueling. Allow heater unit to cool down after operation and wear protective gloves. | |
13 | Bleed coolant circuit after completing installation of STH or HB heater unit (A6) | ||
14 | Start up stationary heater | If the STH or HB heater unit (A6) switches itself off before reaching its operating temperature and cannot be restarted, there is a fault interlock. Eliminate fault interlock: | |
| Connect STAR DIAGNOSIS and read out fault memory | ||
15 | Cooling and heating system - check condition of radiator, lines and hoses | ||
|
Commercially available tools
참조 문서
- ad0000p200004a
- ad0000p200004a Star Diagnosis 연결 후 폴트 메모리 판독
- ah2000n208001a 냉각수 지침
- ap2000p2050g 냉각장치와 히터장치 - 냉각기, 라인, 호스의 상태 점검
- ap2000p2080g 냉각수 교환
- ar0060p1000g 차량 들어 올리기, 정비대 위에 놓기
- ar8370p530201e 히터를 장착한 후 냉매회로를 배기하십시오.
- ar8370p5700gm
- as0000z001001a 리프터에서 차량이 미끄러지거나 틸팅 시 생명의 위험
- as2000z000101a 뜨거운 냉각수 분출 시 입은 화상에 의한 피부와 안구의 상해 위험 냉각수의 음용으로 인한 중독 위험
- as8370z000201a 연료 증발가스에 의한 폭발 위험, 연소가스 흡입으로 인한 중독 위험 및 히터 작동 시 또는 작동 후 화상 위험