1 | Filter drier |
2 | Clip |
3 | Refrigerant line |
4 | Filling connection |
5 | Protective nut |
6 | Electrical shutoff valve |
T83.50-0018-05
| Remove/install | ||
Danger | Risk of explosion caused by welding or soldering work on closed air conditioning system. Risk of poisoning caused by inhaling overheated refrigerant vapors. Risk of injury to skin and eyes caused by contact with liquid refrigerant. | Never perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear safety glasses and protective gloves. Work only in well ventilated areas. Carry out repair work on the air conditioning system circuit only after the system has been drained. | |
Danger | Risk of death caused by falling from vehicle roof. Risk of injury to other persons caused by falling objects during work in roof area. | ||
Topical note | Procedure for a damaged or leaky air conditioning system | ||
Topical note | Protect air conditioning circuit and components from moisture when carrying out repair work | ||
Notes on handling refrigerant R134a | |||
1 | Remove paneling of condenser unit | ||
2 | Remove protective nut (5) over manually operated shutoff valve | ||
3 | Screw in manually operated shutoff valve completely | When the A/C mode is switched off, the electric shutoff valve (6) of the cooling circuit is automatically disabled. | |
4 | Connect A/C suction and recycling equipment to filler connection (4) | Pay attention to the operating instructions of the A/C suction and recycling equipment. | |
5 | Empty closed-off circuit of filter drier (1) via filler connection (4) using A/C suction and recycling equipment | Installation: Evacuate closed-off circuit of filter drier (1) via filler connection (4) using A/C suction and recycling equipment for at least 15 minutes and check for leaktightness. | |
6 | Loosen clamp (2) | ||
7 | Detach refrigerant lines (3) from filter drier (1) | ||
| Compressor oils (specification 362.0) | ||
Installation: Use new sealing rings. Coat sealing rings with compressor oil before installation. | |||
Refrigerant line to filter drier | |||
Warning | Risk of injury caused by damaged assemblies filled with refrigerant | Wear protective clothing, safety gloves and safety glasses. | |
8 | Remove and dispose of filter drier (1) | Installation: | |
9 | Install in the reverse order | ||
10 | Check refrigerant level of air conditioning system | ||
| |||
11 | Perform function test | ||
| Air conditioning system - function check |
참조 문서
- ah8330n000301a 냉매 R134a 취급 관련 지침
- ah8330n000401a 에어컨이 파손되었거나 누출이 있을 경우의 조치
- ah8330n000501a 정비 작업 시 에어컨의 회로와 부품들을 습기로부터 보호하십시오.
- ap8300t8352aa
- ap8330t8312aa
- ar8350t5000aa
- as6500z000201a 차량 루프에서의 추락으로 인한 생명의 위험, 루프 구간에서 작업 시 떨어지는 물체로 인한 타인의 상해 위험
- as8300z000101a 밀폐된 에어컨에서 용접 작업이나 납땜 작업을 실행할 경우 발생할 수 있는 폭발 위험 과열된 냉매 증기의 흡입으로 인한 중독 위험 액체형 냉매와의 피부 및 안구 접촉에 의한 상�
- as8661z000101a 냉매가 주입된 어셈블리의 손상으로 인한 상해 위험
- bb0040p036200a 컴프레서 오일(사양 362.0)