1 | Electrical plug contact |
2 | High pressure switch |
A83.50-0004-06
| Remove/install | ||
Danger | Risk of death caused by falling from vehicle roof. Risk of injury to other persons caused by falling objects during work in roof area. | Model 690.34/63/64, 903.66 (except 903.662), 903.67 | |
Danger | Risk of explosion caused by welding or soldering work on closed air conditioning system. Risk of poisoning caused by inhaling overheated refrigerant vapors. Risk of injury to skin and eyes caused by contact with liquid refrigerant. | Never perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear safety glasses and protective gloves. Work only in well ventilated areas. Carry out repair work on the air conditioning system circuit only after the system has been drained. | |
Topical note | Protect air conditioning circuit and components from moisture when carrying out repair work | Model 690.34/63/64, 903.66 (except 903.662), 903.67 | |
1 | Drain air conditioning system | ||
2 | Detach trim of condenser unit on roof | ||
3 | Disconnect electrical plug contacts (1) from high-pressure switch (2) | ||
4 | Remove high-pressure switch (2) | Installation: Wrap teflon tape around thread of high-pressure switch. | |
Pressure switch | |||
5 | Install in the reverse order | ||
6 | Replace air conditioning system filter drier |
Fluid reservoir |
Number | Designation | Model 690.34 | Model 690.6, 901.6, 902.6, 903.6, 904.6, 905.6 | |
BA83.30-N-1001-03A | Pressure switch | Nm | 12 | 12 |
참조 문서
- ah8330n000501a 정비 작업 시 에어컨의 회로와 부품들을 습기로부터 보호하십시오.
- ar8330a1780b
- ar8350a5000b
- ar8350a5090b
- ar8350a5090b
- as6500z000201a 차량 루프에서의 추락으로 인한 생명의 위험, 루프 구간에서 작업 시 떨어지는 물체로 인한 타인의 상해 위험
- as8300z000101a 밀폐된 에어컨에서 용접 작업이나 납땜 작업을 실행할 경우 발생할 수 있는 폭발 위험 과열된 냉매 증기의 흡입으로 인한 중독 위험 액체형 냉매와의 피부 및 안구 접촉에 의한 상�