1 | Filter drier |
2 | Threaded connection, refrigerant line to inspection glass |
3 | Threaded connection, refrigerant line to evaporator unit |
4 | Securing clamp |
5 | Screw |
A83.50-0005-06
| Remove | ||
Danger | Risk of death caused by falling from vehicle roof. Risk of injury to other persons caused by falling objects during work in roof area. | Model 903.66 (except 903.662), 903.67 | |
Danger | Risk of explosion caused by welding or soldering work on closed air conditioning system. Risk of poisoning caused by inhaling overheated refrigerant vapors. Risk of injury to skin and eyes caused by contact with liquid refrigerant. | Never perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear safety glasses and protective gloves. Work only in well ventilated areas. Carry out repair work on the air conditioning system circuit only after the system has been drained. | |
Topical note | Protect air conditioning circuit and components from moisture when carrying out repair work | Model 690.34/63/64, 903.66 (except 903.662), 903.67 | |
1 | Drain air conditioning system | ||
2 | Remove condenser unit trim from roof | ||
3 | Unscrew threaded connection of refrigerant line from inspection glass (2) | ||
| Compressor oils (specification 362.0) | ||
Installation: Replace seal. Coat sealing ring with compressor oil before installation. | |||
Refrigerant line, fluid reservoir/inspection window | |||
4 | Unscrew threaded connection of refrigerant line from evaporator unit (3) | ||
| Compressor oils (specification 362.0) | ||
Installation: Replace seal. Coat sealing ring with compressor oil before installation. | |||
Refrigerant line, fluid reservoir/inspection window | |||
5 | Remove screw/bolt (5) | Mounting bolt, filter drier to mounting clamp | |
Torque wrench | |||
6 | Remove filter dryer (1) | Installation: Avoid any compressor oil loss in air conditioning system, and replace any compressor oil that may leak out. | |
Model 690.63/64 | |||
Model 690.63/64 | |||
7 | Install in the reverse order | ||
8 | Evacuate air conditioning system and perform leak test | ||
9 | Fill air conditioning system | Fill air conditioning system, replenish (gaseous) | |
Fill air conditioning system (liquid) |
Rear air conditioning |
Number | Designation | Model 690.34 | Model 690.63/64 | |
BA83.50-N-1008-01B | Refrigerant line, fluid reservoir/inspection window | Nm | 35 | 35 |
Rear air conditioning |
Number | Designation | Model 690.34 | Model 690.63/64 | |
BA83.50-N-1009-01B | Mounting bolt, filter drier to mounting clamp | Nm | 18 | 18 |
Air conditioning |
Number | Designation | Model 690.63/64 | Model 901.6, 902.6, 904.6 (except 904.663), 905.6 (except 905.613) | ||
BF83.30-N-1001-01A | Total compressor oil filling capacity for new system (in refrigerant compressor) | cm3 | 160 | – | |
Sheet | - | ||||
Air conditioning |
Number | Designation | Model 903.661 | Model 903.661 | ||
BF83.30-N-1001-01A | Total compressor oil filling capacity for new system (in refrigerant compressor) | cm3 | 220 | 160 | |
Sheet | |||||
Air conditioning |
Number | Designation | Model 690.63/64 | Model 901.6, 902.6, 904.6 (except 904.663), 905.6 (except 905.613) | ||
BF83.30-N-1011-01A | Total compressor oil filling capacity of air conditioning system (including refrigerant compressor) | cm3 | 360 | 145 | |
Sheet | |||||
Air conditioning |
Number | Designation | Model 903.661 | Model 903.661 | ||
BF83.30-N-1011-01A | Total compressor oil filling capacity of air conditioning system (including refrigerant compressor) | cm3 | 300 | 410 | |
Sheet | |||||
000 589 67 21 00
Torque wrench
참조 문서
- ah8330n000501a 정비 작업 시 에어컨의 회로와 부품들을 습기로부터 보호하십시오.
- ar8330a1762b
- ar8330a1767b
- ar8330a1777b
- ar8330a1780b
- ar8350a5000b
- as6500z000201a 차량 루프에서의 추락으로 인한 생명의 위험, 루프 구간에서 작업 시 떨어지는 물체로 인한 타인의 상해 위험
- as8300z000101a 밀폐된 에어컨에서 용접 작업이나 납땜 작업을 실행할 경우 발생할 수 있는 폭발 위험 과열된 냉매 증기의 흡입으로 인한 중독 위험 액체형 냉매와의 피부 및 안구 접촉에 의한 상�
- bb0040p036200a 컴프레서 오일(사양 362.0)