1 | Fluid reservoir |
2 | Union nuts |
3 | Nuts |
W83.30-1095-12
Danger ! | Risk of explosion caused by welding or soldering work on closed air conditioning system. Risk of poisoning caused by inhaling overheated refrigerant vapors. Risk of injury to skin and eyes caused by contact with liquid refrigerant. | Never perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear safety glasses and protective gloves. Work only in well ventilated areas. Carry out repair work on the air conditioning system circuit only after the system has been drained. | |
| Protect air conditioning circuit and components from moisture when carrying out repair work | ||
| Notes on handling refrigerant R134a | ||
| Remove/install | ||
1 | Drain air conditioning system | ||
2 | Unscrew union nuts (2) and remove refrigerant lines from fluid reservoir (1) | Do not bend refrigerant lines. | |
Installation: Replace gaskets. | |||
Union nut for refrigerant lines to fluid reservoir | |||
3 | Unscrew nuts (3) | Nut, fluid reservoir to bracket | |
4 | Remove fluid reservoir (1) | Installation: Replace O-rings. | |
If the fluid reservoir (1) is replaced | |||
| |||
Add oil filling capacity of refrigerant circuit | |||
Additional oil filling quantity after replacing fluid reservoir | |||
5 | Disconnect electrical connector from fluid reservoir (1) | Installation: Replace cable tie. | |
6 | Install in the reverse order | ||
7 | Check air conditioning for proper operation |
참조 문서
- ah8330n000301a 냉매 R134a 취급 관련 지침
- ah8330n000501a 정비 작업 시 에어컨의 회로와 부품들을 습기로부터 보호하십시오.
- ar8330w1760a 에어컨 비운 후 진공 상태로 하여 새로 주입, 기능 및 기밀성 점검
- as8300z000101a 밀폐된 에어컨에서 용접 작업이나 납땜 작업을 실행할 경우 발생할 수 있는 폭발 위험 과열된 냉매 증기의 흡입으로 인한 중독 위험 액체형 냉매와의 피부 및 안구 접촉에 의한 상�