AR83.30-P-6540MCC | Remove/install condenser | 21.8.07 |
MODEL 451.3 /4 with CODE (I01) Air conditioning Plus
P83.30-4474-05
1 Capacitor
2 Refrigerant line
3 Nut
4 Catch
| Remove/install | ||
Danger! | Risk of explosion caused by welding or soldering work on closed air conditioning system. Risk of poisoning caused by inhaling overheated refrigerant vapors. Risk of injury to skin and eyes caused by contact with liquid refrigerant. | Never perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear safety glasses and protective gloves. Work only in well ventilated areas. Carry out repair work on the air conditioning system circuit only after the system has been discharged. | |
| Procedure for a damaged or leaky air conditioning system | ||
| Protect air conditioning circuit and components from moisture when carrying out repair work | ||
| Notes on handling refrigerant R134a | ||
1 | Remove front module | ||
2 | Discharge air conditioning system | Installation: Evacuate air conditioning and then fill. | |
3 | Unscrew nut (3) from condenser (1) and detach refrigerant lines (2) from condenser (1) | Close off refrigerant lines (2) and condenser (1) using appropriate stop plugs, as otherwise penetrating dirt and moisture damage components that are connected to the refrigerant circuit. | |
Installation: Replace seal rings on refrigerant lines (2). | |||
4 | Unclip condenser (1) from catch (4), swivel forwards at the left-hand side and remove | ||
5 | Remove filter dryer | Installation: Always replace the filter drier after opening the refrigerant circuit. | |
6 | Install in the reverse order |